A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Agreement between the ventilated capsule and the KuduSmart® device for measuring sweating responses to passive heat
Nicholas Ravanelli1,2, Douglas Newhouse1,2, Fergus Foster1
1School of Kinesiology, Lakehead University, Thunder Bay, ON, Canada.
Abstract:
The present study assessed agreement between a wireless sweat rate monitor (KuduSmart® device) and the ventilated capsule (VC) technique for measuring: (i) minute-averaged local sweat rate (LSR), (ii) sweating onset, (iii) sudomotor thermosensitivity, and (iv) steady-state LSR, during passive heat stress and exercise. It was hypothesized that acceptable agreement with no bias would be observed between techniques for all assessed sweating characteristics. On two separate occasions for each intervention, participants were either passively heated by recirculating hot water (49 °C) through a tube-lined garment until rectal temperature increased 1 °C over baseline (n = 8), or a 60 min treadmill march at a fixed rate of heat production (∼500 W, n = 9). LSR of the forearm was concurrently measured with a VC and the KuduSmart® device secured within ∼2 cm. Using a ratio scale Bland-Altman analysis with the VC as the reference, the KuduSmart® device demonstrated systematic bias and not acceptable agreement for minute-averaged LSR (1.17 [1.09, 1.27], CV = 44.5%), systematic bias and acceptable agreement for steady-state LSR (1.16 [1.09,1.23], CV = 19.5%), no bias and acceptable agreement for thermosensitivity (1.07 [0.99, 1.16], CV = 23.2%), and no bias and good agreement for sweating onset (1.00 [1.00, 1.00], CV = 11.1%). In total, ≥73% of all minute-averaged LSR observations with the KuduSmart® device (n = 2743) were within an absolute error of <0.2 mg/cm2/min to the VC, the reference minimum detectable change in measurement error of a VC on the forearm. Collectively, the KuduSmart® device may be a satisfactory solution for assessing the sweating response to heat stress where a VC is impractical.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Responses to Heat and Cold Stress
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Accessory Structures of the Skin: Sweat Glands
Sweat glands are classified as merocrine glands; that is, the secretions are excreted by exocytosis through a duct without affecting the cells of the gland. There...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Thermal Stress