Related Experiment Video
Updated: Jul 19, 2025

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Ultra-high-resolution spectral silicon-based photon-counting detector CT for coronary CT angiography: Initial results
Thomas Wesley Holmes1, Zhye Yin2, Grant M Stevens2
1Department of Radiology and Imaging Sciences, Emory University, 1364 Clifton Road NE, Atlanta, GA 30322, USA.
Background:
Recent improvements in CT detector technology have led to smaller detector pixels resolving frequencies beyond 20 lp/cm and enabled ultra-high-resolution CT. Silicon-based photon-counting detector (PCD) CT is one such technology that promises improved spatial and spectral resolution. However, when the detector pixel sizes are reduced, the impact of cardiac motion on CT images becomes more pronounced. Here, we investigated the effects cardiac motion on the image quality of a clinical prototype Si-PCD scanner in a dynamic heart phantom.
Methods:
A series of 3D-printed vessels were created to simulate coronary arteries with diameter in the 1-3.5 mm range. Four coronary stents were set inside the d = 3.5 mm vessels and all vessels were filled with contrast agents and were placed inside a dynamic cardiac phantom. The phantom was scanned in motion (60 bpm) and at rest on a prototype clinical Si-PCD CT scanner in 8-bin spectral UHR mode. Virtual monoenergetic images (VMI) were generated at 70 keV and CT number accuracy and effective spatial resolution (blooming) of rest and motion VMIs were compared.
Results:
Linear regression analysis of CT numbers showed excellent agreement (r > 0.99) between rest and motion. We did not observe a significant difference (p > 0.48) in estimating free lumen diameters. Differences in in-stent lumen diameter and stent strut thickness were non-significant with maximum mean difference of approximately 70 μm.
Conclusion:
We found no significant degradation in CT number accuracy or spatial resolution due to cardiac motion. The results demonstrate the potential of spectral UHR coronary CT angiography enabled by Si-PCD.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...