Diagnostic Performance of Contrast-Enhanced Digital Mammography versus Conventional Imaging in Women with Dense
Giuliana Moffa1, Francesca Galati1, Roberto Maroncelli1
1Department of Radiological, Oncological and Pathological Sciences, Sapienza University of Rome, 00161 Rome, Italy.
Abstract:
The aim of this prospective study was to compare the diagnostic performance of contrast-enhanced mammography (CEM) versus digital mammography (DM) combined with breast ultrasound (BUS) in women with dense breasts. Between March 2021 and February 2022, patients eligible for CEM with the breast composition category ACR BI-RADS c-d at DM and an abnormal finding (BI-RADS 3-4-5) at DM and/or BUS were considered. During CEM, a nonionic iodinated contrast agent (Iohexol 350 mg I/mL, 1.5 mL/kg) was power-injected intravenously. Images were evaluated independently by two breast radiologists. Findings classified as BI-RADS 1-3 were considered benign, while BI-RADS 4-5 were considered malignant. In case of discrepancies, the higher category was considered for DM+BUS. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated, using histology/≥12-month follow-up as gold standards. In total, 51 patients with 65 breast lesions were included. 59 (90.7%) abnormal findings were detected at DM+BUS, and 65 (100%) at CEM. The inter-reader agreement was excellent (Cohen's k = 0.87 for DM+BUS and 0.97 for CEM). CEM showed a 93.5% sensitivity (vs. 90.3% for DM+BUS), a 79.4-82.4% specificity (vs. 32.4-35.5% for DM+BUS) (McNemar p = 0.006), a 80.6-82.9% PPV (vs. 54.9-56.0% for DM+BUS), a 93.1-93.3% NPV (vs. 78.6-80.0% for DM+BUS), and a 86.1-87.7% accuracy (vs. 60.0-61.5% for DM+BUS). The AUC was higher for CEM than for DM+BUS (0.865 vs. 0.613 for Reader 1, and 0.880 vs. 0.628, for Reader 2) (p < 0.001). In conclusion, CEM had a better diagnostic performance than DM and BUS alone and combined together in patients with dense breasts.
More Related Videos
13:44Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
X-ray Imaging
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies III: Computed Tomography