The Design of an Automatic Temperature Compensation System through Smart Heat Comparison/Judgment and Control for
Kicheol Yoon1,2, Sangyun Lee1,2, Tae-Hyeon Lee3
1Medical Devices R&D Center, Gachon University Gil Medical Center, 21, 774 Beon-gil, Namdong-daero, Namdong-gu, Incheon 21565, Republic of Korea.
Abstract:
After surgery for ovarian cancer or colorectal cancer, residual tumors are left around. A practical way to treat residual tumors is to destroy them with heat by injecting high-temperature drugs into the abdominal cavity. The injected medicinal substances are induced to flow out of the abdominal cavity; then, the spilled drug flows back into the abdominal cavity through feedback. During this process, the heat starts to decrease; thus, the treatment performance reduces. To overcome this problem, this study compares and assesses the temperature needed to maintain the heat for treatment and transmits a command signal to the heat exchanger through a look-up table (LUT). When the temperature decreases during the circulation of medications leaking out of the abdominal cavity, the LUT transmits a control signal (T) to the heat exchanger, which increases or vice versa. However, if the temperature (T) is within the treatment range, the LUT sends a T signal to the heat exchanger. This principle generates a pulse signal for the temperature difference (T) in TC by comparing and determining the temperature (T) of the substance flowing out of the abdominal cavity with the reference temperature (T) through the temperature comparator (TC). At this time, if the signal is 41 °C or less, the LUT generates (heats) a T signal so that the temperature of the heat exchanger can be maintained in the range of 41 °C to 43 °C. If the T is 44 °C or higher, the LUT generates (cools) the Ta signal and maintains the temperature of the heat exchanger at 41-43 °C. If the T is maintained at 41-43 °C, the LUT generates a T signal to stop the system performance. At this time, the TC operation performance and T generation process for comparing and determining the signal of T and T for drugs leaking out of the abdominal cavity is very important. It was observed that the faster the response signal, the lower the comparison and judgment error was; therefore, the response signal was confirmed to be 0.209 μs. The proposed method can guarantee rapid/accurate/safe treatment and automatically induce temperature adjustment; thus, it could be applied to the field of surgery.
More Related Videos
10:23Author Spotlight: Computing the Effects of a Local Radiofrequency Hyperthermia Intervention on Tumor Biomechanics
Published on: December 1, 2023
07:47Custom-designed Laser-based Heating Apparatus for Triggered Release of Cisplatin from Thermosensitive Liposomes with Magnetic Resonance Image Guidance
Published on: December 13, 2015
Related Concept Videos
Decreased Body Temperature
PID Controller
Methods of reducing fever
Pharmacological Methods of Reducing Fever:
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...