An Adaptive Virtual Impedance Method for Grid-Connected Current Quality Improvement of a Single-Phase Virtual
Caomao Zhong1,2, Zhi Zhang1, Anan Zhu1
1Department of Electrical Engineering and Automation, Dongguan University of Technology, Dongguan 523808, China.
Abstract:
The proportion of distributed generation systems in power grids is increasing, leading to the gradual emergence of weak grid characteristics. Moreover, using voltage-sourced grid-connected inverters can enhance the stability of a weak grid. However, due to the presence of background harmonics in weak grids, the grid voltage can cause significant distortions in the grid-connected current, which adversely affects the quality of the grid-connected current. This paper begins by briefly introducing the principle of the virtual synchronous generator (VSG). Then, the output current of the voltage source inverter is analyzed to elucidate the mechanism of harmonic current generation. Considering the distortion in the grid-connected current of the voltage source grid-connected inverter caused by background harmonics in the grid voltage, a harmonic current suppression strategy based on an adaptive virtual harmonic resistor is proposed. The proposed strategy employs a signal separation module based on multiple second-order generalized integrators connected through a cross-feedback network. This module effectively separates the fundamental and harmonic currents from the grid-connected current, extracts the amplitudes of the fundamental and harmonic currents through coordinate transformation, and adaptively adjusts the virtual harmonic resistance magnitude through the negative feedback control of the harmonic content (the ratio of the harmonic current amplitude to the fundamental current amplitude). These measures are used to enhance the quality of the grid-connected current. Additionally, the stability of the system is analyzed using the root locus of the open-loop transfer function. Finally, the effectiveness of the proposed method is validated through a combination of MATLAB/Simulink simulations and experimental results.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
07:51Voltage Biasing, Cyclic Voltammetry, & Electrical Impedance Spectroscopy for Neural Interfaces
Published on: February 24, 2012
Related Concept Videos
Generator Voltage Control
Generation of Three-Phase Voltage
As the rotor...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Power System Three-Phase Short Circuits
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...