Precision of measurements of right and left ventricular volume by cine computed tomography
Insights
Cine computed tomography (CT) precisely measures right and left ventricular stroke volumes, overcoming limitations of conventional methods. This advanced imaging technique offers highly reproducible results for accurate cardiac assessment.
Area of Science:
- Cardiovascular Imaging
- Medical Physics
- Diagnostic Radiology
Background:
- Conventional imaging techniques have limitations in precisely determining left and right ventricular stroke volumes.
- Accurate measurement of ventricular stroke volumes is crucial for assessing cardiac function.
Purpose of the Study:
- To evaluate the precision and reproducibility of cine computed tomography (CT) for measuring right and left ventricular stroke volumes.
- To compare cine CT measurements with established methods for determining stroke volume.
Main Methods:
- Cine CT was used to simultaneously image both ventricles in eight dogs.
- True ventricular stroke volumes were determined using thermodilution cardiac output and/or an electromagnetic flow probe.
- Stroke volumes were calculated using Simpson's reconstruction from short-axis tomograms acquired during contrast injection.
Main Results:
- Cine CT left ventricular stroke volume showed high correlation with true stroke volume (r = .99).
- Cine CT right ventricular stroke volume also showed high correlation with true stroke volume (r = .98).
- Measurements demonstrated minimal intraobserver and interobserver variability, indicating high reproducibility.
Conclusions:
- Cine CT provides precise and highly reproducible measurements of both right and left ventricular stroke volumes.
- This technique offers a valuable tool for accurate cardiac function assessment, overcoming limitations of traditional methods.
Abstract:
Precise determination of left and right ventricular stroke volumes is limited with conventional imaging techniques. We determined whether right and left ventricular stroke volumes could be precisely measured with cine computed tomography (CT). Cine CT enables simultaneous imaging of the right and left ventricles at an 8 mm slice thickness with a maximal scanning rate of 17 frames/sec (50 msec acquisition intervals). In eight dogs, true right ventricular and left ventricular stroke volumes were determined by dividing thermodilution cardiac output by heart rate and/or with the use of an aortic electromagnetic flow probe implanted over a long term. After at least 5 sec of suspended respiration, cine CT images were acquired during central venous injection of a nonionic contrast agent. Multiple perturbations in stroke volume were induced in each dog by the administration of dobutamine, sodium pentobarbital, or sodium nitroprusside or by coronary artery occlusion. Right and left ventricular stroke volumes were obtained by Simpson's reconstruction of end-diastolic and end-systolic short-axis tomograms from apex to base. The cine CT left ventricular stroke volume (range 11 to 45 ml) correlated highly with the true left ventricular stroke volume (r = .99, slope = 1.01, y intercept = -0.2 ml, SEE = 1.5 ml, n = 25). The cine CT right ventricular stroke volume (range 11 to 34 ml) also correlated highly with the true right ventricular stroke volume (r = .98, slope = 0.9, y intercept = 2.2 ml, SEE = 1.7 ml, n = 15). In 12 studies, the mean difference between nearly simultaneous right and left ventricular stroke volumes by cine CT was 1.1 ml (range 0.1 to 3.2 ml). Calculation of right and left ventricular stroke volumes from data from cine CT were highly reproducible. Intraobserver variability in measurements of right ventricular stroke volume (r = 1.0, slope = 0.99, y intercept = 0.19 ml) and left ventricular stroke volume (r = 1.0, slope = 1.02, y intercept = -0.21 ml) was minimal. Interobserver variability in measurements of right ventricular stroke volume (r = .98, slope = 0.90, y intercept = 1.66 ml) and left ventricular stroke volume (r = .99, slope = 0.97, y intercept = -0.02 ml) was likewise minimal. Thus, precise and highly reproducible measurements of right and left ventricular stroke volumes can be obtained with cine CT.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...