Related Experiment Video
Updated: Jul 19, 2025

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Internal jugular vein collapsibility does not predict fluid responsiveness in spontaneously breathing patients after
Jan Horejsek1, Martin Balík1, Jan Kunstýř1
1Department of Anaesthesiology and Intensive Care Medicine, First Faculty of Medicine, Charles University in Prague and General University Hospital in Prague, Prague, 12808, Czech Republic.
Purpose:
The objective of our study was to evaluate the diagnostic accuracy of internal jugular vein (IJV) collapsibility as a predictor of fluid responsiveness in spontaneously breathing patients after cardiac surgery.
Methods:
In this prospective observational study, spontaneously breathing patients were enrolled on the first postoperative day after coronary artery bypass grafting. Hemodynamic data coupled with simultaneous ultrasound assessment of the IJV were collected at baseline and after passive leg raising test (PLR). Continuous cardiac index (CI), stroke volume (SV), and stroke volume variation (SVV) were assessed with FloTracTM/EV1000™. Fluid responsiveness was defined as an increase in CI ≥ 10% after PLR. We compared the differences in measured variables between fluid responders and non-responders and tested the ability of ultrasonographic IJV indices to predict fluid responsiveness.
Results:
Fifty-four patients were included in the study. Seventeen (31.5%) were fluid responders. The responders demonstrated significantly lower inspiratory and expiratory diameters of the IJV at baseline, but IJV collapsibility was comparable (P = 0.7). Using the cut-off point of 20%, IJV collapsibility predicted fluid responsiveness with a sensitivity of 76.5% and specificity of 38.9%, ROC AUC 0.55.
Conclusion:
In spontaneously breathing patients after surgical coronary revascularisation, collapsibility of the internal jugular vein did not predict fluid responsiveness.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Aneurysm IV: Nursing Management
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Aortic Regurgitation IV: Nursing Management
Cardiopulmonary Resuscitation II: ACLS Airway Management
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...

