Related Experiment Video
Updated: Jul 19, 2025

A Zebrafish Model of Diabetes Mellitus and Metabolic Memory
Published on: February 28, 2013
Efficacy and safety of closed-loop control system for type one diabetes in adolescents a meta analysis
1Department of Pediatrics, Imam Mohammed Ibn Saud Islamic University, An Nada, 13317, Riyadh, Saudi Arabia. majabari@imamu.edu.sa.
Abstract:
This meta-analysis compares the efficacy and safety of Closed-Loop Control (CLC) to Sensor-Augmented Insulin Pump (SAP) for adolescent patients with Type 1 Diabetes Mellitus (T1DM). Eleven randomized-controlled trials were included with a total of 570 patients, from a total of 869 articles found adhering to PRISMA guidelines. The efficacy of the therapies were evaluated from the day, night and during physical activities monitoring of the of the mean blood glucose (BG), Time In Range (TIR), and Standard Deviation (SD) of the glucose variability. The safety measure of the therapies, was assessed from the day and night recording of the hypoglycemic and hyperglycemic events occurred. Pooled results of comparison of mean BG values for day, night and physical activities, - 4.33 [- 6.70, - 1.96] (P = 0.0003), - 16.61 [- 31.68, - 1.54] (P = 0.03) and - 8.27 [- 19.52, 2.99] (P = 0.15). The monitoring for day, night and physical activities for TIR - 13.18 [- 19.18, - 7.17] (P < 0.0001), - 15.36 [- 26.81, - 3.92] (P = 0.009) and - 7.39 [- 17.65, 2.87] (P = 0.16). The day and night results of SD of glucose variability was - 0.40 [- 0.79, - 0.00] (P = 0.05) and - 0.86 [- 2.67, 0.95] (P = 0.35). These values shows the superiority of CLC system in terms of efficacy. The safety evaluation, of the day, night and physical activities observations of average blood glucose goal hypoglycemic events - 0.54 [- 1.86, 0.79] (P = 0.43), 0.04 [- 0.20, 0.27] (P = 0.77) and 0.00 [- 0.25, 0.25] (P = 1.00) and hyperglycemic events - 0.04 [- 0.20, 0.27] (P = 0.77), - 7.11 [- 12.77, - 1.45] (P = 0.01) and - 0.00 [- 0.10, 0.10] (P = 0.97), highlights the commendable safety factor of CLC. The CLC systems can be considered as an ideal preference in the management of adolescents with type 1 diabetes to be used during a 24 h basis.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...
Diabetes Mellitus: Type 2 and Gestational
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...