Related Experiment Video
Updated: Jul 19, 2025

Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
Optimization of enzyme-linked immunosorbent assay kit protocol to detect trimethylamine N-oxide levels in humans
Zinnet Sevval Aksoyalp1, Betül Rabia Erdogan1, Saliha Aksun2
1Izmir Katip Celebi University, Faculty of Pharmacy, Department of Pharmacology, Izmir, TR.
Abstract:
The serum level of trimethylamine N-oxide (TMAO), a gut microbiota metabolite associated with diabetes, cancer, inflammatory and neurological diseases, can be determined by the micro-enzyme-linked immunosorbent assay (ELISA) method. However, we had problems obtaining accurate standard curves with the original kit protocol from Bioassay Technology Laboratory. We aimed to acquire proper standard curves by modifying the kit protocol in this study. First, we evaluated the human TMAO ELISA kit protocols and other human ELISA kits. We maintained the incubation times longer and increased the wash cycle. Moreover, we incubated the standards containing biotinylated antibody in the wells alone. Then we washed the wells and added streptavidin-HRP for the second incubation step. The data of original and modified ELISA kit protocol were analyzed with Student's t-test. We measured higher absorbance with lower standard solution concentration in experiments that followed the original kit protocol. After investigating other human TMAO ELISA kits, we noticed that the SunRed Biotechnology Company and MyBioSource companies suggested similar protocols to the Bioassay Technology Laboratory company. The ELK Biotechnology ELISA protocol was different from others. However, since there is no biotinylated antibody in the standard solution in the ELK biotechnology kit, we changed some steps by examining other human ELISA protocols from different companies. After performing the modified protocol, we found that the absorbances of the standard solutions were consistent with their concentrations, and we obtained an accurate standard curve. Higher R2 values and lower absolute difference of standard concentrations were found in the modified kit protocol. The human TMAO ELISA protocol, which we modified in this study, will enable researchers to obtain more reliable results and prevent them from failing time and resources.
More Related Videos
04:19Author Spotlight: An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
08:26Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018