Optimal bi-planar gradient coil configurations for diamond nitrogen-vacancy based diffusion-weighted NMR experiments.
Philipp Amrein1, Fleming Bruckmaier2, Feng Jia3
1Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Killianstrasse 5a, 79106, Freiburg, Germany. philipp.amrein@uniklinik-freiburg.de.
Optimizing bi-planar gradient coils for diamond nitrogen-vacancy (NV) center NMR diffusion experiments is crucial. Inclined coil orientations enhance sensitivity for microstructural analysis, simplifying experimental setup.
Area of Science:
- Physics
- Materials Science
- Engineering
Background:
- Optically detected magnetic resonance (ODMR) with diamond nitrogen-vacancy (NV) centers offers microstructural insights via diffusion weighting.
- Bi-planar gradient coils are essential for diffusion weighting in NV-NMR, providing necessary spatial access.
- The polar tilt of the diamond NV center necessitates careful consideration of the primary magnetic field direction.
Purpose of the Study:
- To investigate optimal bi-planar gradient coil configurations for NV-NMR diffusion experiments.
- To determine the impact of coil geometry (side length, separation, orientation) on performance.
- To identify coil designs that balance sensitivity, field accuracy, and experimental integration.
Main Methods:
- Automated generation of over 500 bi-planar surface coil configurations.
- Evaluation of coil layouts based on sensitivity and magnetic field accuracy.
- Fabrication and experimental validation of a three-channel bi-planar double-layered PCB coil system.
Main Results:
- Inclined bi-planar coil orientations demonstrated superior sensitivity for transverse gradient channels compared to horizontal or vertical setups.
- Experimental validation confirmed sensitivities for transverse (x, y) and longitudinal (z) gradients.
- A relative bi-planar tilt of [Formula: see text] was identified as optimal.
Conclusions:
- The optimized bi-planar coil configuration with a [Formula: see text] tilt offers a practical compromise for NV-NMR diffusion experiments.
- This design facilitates easier coil implementation within the experimental setup.
- The findings contribute to advancing microstructural analysis using diamond NV centers.
Related Concept Videos
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Two-Dimensional (2D) NMR: Overview
The first step is the preparation period, during which nucleus A is excited with a radiofrequency pulse....
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
2D NMR: Overview of Heteronuclear Correlation Techniques
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule
NMR Spectroscopy: Spin–Spin Coupling