Related Experiment Video
Updated: Jul 19, 2025

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Quality in colonoscopy: time to ensure national standards are implemented?
Laura J Neilson1,2,3, Rosie Dew4, James S Hampton1
1Department of Gastroenterology, South Tyneside and Sunderland NHS Foundation Trust, South Shields, UK.
Background:
High-quality colonoscopy is crucial to ensure complete mucosal visualisation and to maximise detection of pathology. Previous audits showing variable quality have prompted national and international colonoscopy improvement programmes, including the development of quality assurance standards and key performance indicators (KPIs). The most widely used marker of mucosal visualisation is the adenoma detection rate (ADR), however, histological confirmation is required to calculate this. We explored the relationship between core colonoscopy KPIs.
Methods:
Data were collected from colonoscopists in eight hospitals in North East England over a 6-month period, as part of a quality improvement study. Procedural information was collected including number of colonoscopies, caecal intubation rate (CIR), ADR and polyp detection rate (PDR). Associations between KPIs and colonoscopy performance were analysed.
Results:
9265 colonoscopies performed by 118 endoscopists were included. Mean ADR and PDR per endoscopist were 16.6% (range 0-36.3, SD 7.4) and 27.2% (range 0-57.5, SD 9.3), respectively. Mean number of colonoscopies conducted in 6 months was 78.5 (range 4-334, SD 61). Mean CIR was 91.2% (range 55.5-100, SD 6.6). Total number of colonoscopies and ADR>15% were significantly associated (p=0.04). Undertaking fewer colonoscopies and using hyoscine butylbromide less frequently was significantly associated with ADR<15%. CIR, endoscopist grade, % male patients, mean patient age and CIR were not significantly related to ADR<15%. In adjusted analyses, factors which affected ADR were PDR and mean patient age.
Conclusion:
Colonoscopists who perform fewer than the nationally stipulated minimum of 100 procedures per year had significantly lower ADRs. This study demonstrates that PDR can be used as a marker of ADR; providing age is also considered.
More Related Videos
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Standards of Care II