Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Use of Wearable Devices for Peak Oxygen Consumption Measurement in Clinical Cardiology: Case Report and Literature
Gabriella Bayshtok1,2, Shmuel Tiosano1,2,3, Ariel Furer3,4
1Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Background:
Oxygen consumption is an important index to evaluate in cardiac patients, particularly those with heart failure, and is measured in the setting of advanced cardiopulmonary exercise testing. However, technological advances now allow for the estimation of this parameter in many consumer and medical-grade wearable devices, making it available for the medical provider at the initial evaluation of patients. We report a case of an apparently healthy male aged 40 years who presented for evaluation due to an Apple Watch (Apple Inc) notification of low cardiac fitness. This alert triggered a thorough workup, revealing a diagnosis of familial nonischemic cardiomyopathy with severely reduced left ventricular systolic function. While the use of wearable devices for the measurement of oxygen consumption and related parameters is promising, further studies are needed for validation.
Objective:
The aim of this report is to investigate the potential utility of wearable devices as a screening and risk stratification tool for cardiac fitness for the general population and those with increased cardiovascular risk, particularly through the measurement of peak oxygen consumption (VO2). We discuss the possible advantages of measuring oxygen consumption using wearables and propose its integration into routine patient evaluation and follow-up processes. With the current evidence and limitations, we encourage researchers and clinicians to explore bringing wearable devices into clinical practice.
Methods:
The case was identified at Sheba Medical Center, and the patient's cardiac fitness was monitored through an Apple Watch Series 6. The patient underwent a comprehensive cardiac workup following his presentation. Subsequently, we searched the literature for articles relating to the clinical utility of peak VO2 monitoring and available wearable devices.
Results:
The Apple Watch data provided by the patient demonstrated reduced peak VO2, a surrogate index for cardiac fitness, which improved after treatment initiation. A cardiological workup confirmed familial nonischemic cardiomyopathy with severely reduced left ventricular systolic function. A review of the literature revealed the potential clinical benefit of peak VO2 monitoring in both cardiac and noncardiac scenarios. Additionally, several devices on the market were identified that could allow for accurate oxygen consumption measurement; however, future studies and approval by the Food and Drug Administration (FDA) are still necessary.
Conclusions:
This case report highlights the potential utility of peak VO2 measurements by wearable devices for early identification and screening of cardiac fitness for the general population and those at increased risk of cardiovascular disease. The integration of wearable devices into routine patient evaluation may allow for earlier presentation in the diagnostic workflow. Cardiac fitness can be serially measured using the wearable device, allowing for close monitoring of functional capacity parameters. Devices need to be used with caution, and further studies are warranted.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring