Microfluidic flow injection analysis system for the electrochemical detection of dopamine using diazonium-grafted
Yilei Xue1, Qusai Hassan1, Meissam Noroozifar2
1Department of Physical and Environmental Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario, M1C 1A4, Canada; Department of Chemistry, University of Toronto, 80 St. George Street, Toronto, Ontario, M5S 3H6, Canada.
Abstract:
In this proof-of-concept study, a microfluidic flow injection analysis (FIA) system was developed using multi-walled carbon nanotube-modified screen-printed carbon electrodes (CNTSPEs) that were modified with copper nanoparticles (CuNPs) following the electrodeposition of the diazonium salt of 4-aminothiophenol to form 4-thiophenol-conjugated CuNPs (CuNPs-CNTSPE). Transmission electron microscopy (TEM), atomic force microscopy (AFM), and scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDS) were used to characterize the size of CuNPs, morphology and elemental analysis of CuNPs-CNTSPE, respectively. Using electrochemical impedance spectroscopy (EIS), the charge-transfer resistance (Rct) of CuNPs-CNTSPE was found to be 20-fold lower than that of CNTSPE. The CuNPs-CNTSPE displayed an oxidation peak for dopamine at -0.08 V which is ∼80 mV lower than the one detected using CNTSPE. The modified electrode was used in microfluidic flow injection analysis and offline systems for sensitive detection of dopamine (DA). The pH, flow rate, loop volume, concentration, and type of surfactant were all optimized for on-chip detection. Under the optimal conditions, using phosphate electrolyte solution (pH 6) containing 0.05% (w/v) Tween 20® as the carrier at a flow rate of 0.6 mL min-1 and a loop volume of 50 μL, the calibration curve was linear from 1.5 to 500 nM with a limit of detection of 0.33 nM. This technique was used for the successful detection of DA in real samples with recovery ranging from 96.5% to 103.8%. The microfluidic FIA system described here has the potential to be used as an electrochemical point-of-care device for rapid DA detection with high sensitivity and reproducibility.
More Related Videos
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017
07:34Gold Nanoparticle Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection
Published on: May 13, 2019