Related Experiment Video
Updated: Jul 19, 2025

Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
Optimisation of plutonium separations using TEVA cartridges and ICP-MS/MS analysis for applicability to large-scale
Sophia M Dowell1,2, Thomas S Barlow1, Simon R Chenery1
1Inorganic Geochemistry, Centre for Environmental Geochemistry, British Geological Survey, Nottingham, NG12 5GG, UK. mwatts@bgs.ac.uk.
Abstract:
The analysis of plutonium (Pu) in soil samples can inform the understanding of soil erosion processes globally. However, there are specific challenges associated for analysis in tropical soils and so an optimal analytical methodology ensuring best sensitivity is critical. This method aimed to demonstrate the feasibility of sample preparation and analysis of Pu isotopes in African soils, considering the environmental and cost implications applicable to low-resource laboratories. The separation procedure builds upon previous work using TEVA columns, further demonstrating their usefulness for the reduction of uranium (U) interference in ICP-MS analysis with enhanced selectivity for Pu. Here several steps were optimised to enhance Pu recovery, reducing method blank concentration, and improving the separation efficiency through the determination of the elution profiles of U and Pu. The elimination of the complexing agent in the eluent, increased the spike recovery by improving matrix tolerance of the plasma, and simplified the separation procedure, improving throughput by 20%. The subsequent method was validated through the analysis of Certified Reference Material IAEA-384, where high accuracy and improved precision of measurement were demonstrated (measured value 114 ± 12 versus certified value 108 ± 13 Bq kg-1). Optimisation of the column separation, along with the analysis of the samples using O2 gas in ICP-MS/MS mode to mass shift Pu isotopes away from interfering molecular U ions provided a simple, robust, and cost-effective method with low achievable method detection limits of 0.18 pg kg-1 239+240Pu, applicable to the detection of ultra-trace fallout Pu in African soils.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences