Usability of a continuous oxygen saturation device for home telemonitoring
Francesco Bonometti1, Palmira Bernocchi1, Andrea Vitali2
1Istituti Clinici Scientifici Maugeri IRCCS, Continuity of Care Service of the Institute of Lumezzane, Brescia, Italy.
Background:
The emergency for the COVID-19 pandemic has led to greater use of home telemonitoring devices. The aim of this study was to assess the usability of continuous home-monitoring care with an oxygen saturation device on post-COVID-19 patients.
Method:
The system consists of a digital continuous pulse oximeter and a smartphone with an App, which were provided to patients. A survey composed of a standard Post-Study System Usability Questionnaire, and a satisfaction questionnaire was exploited to conduct a usability and feasibility analysis of the service.
Results:
A total of 29 patients (17.2% female) with a mean age of 65 ± 11.5 years were enrolled: 20 patients were smartphone users (69%) with a mean age of 60.2 ± 9.5 years, and 9 patients (31%) did not own a smartphone (mean age 76.8 ± 5.9). The monitoring period was 1 month: a total of 444 recordings were conducted, 15 recordings per patient averagely. In total, 82% of the recordings performed did not require any intervention, while 18% led to the production of a report and subsequent intervention by a nurse who verified, together with the specialist, the need to intervene (i.e. the patient accessed the clinic for medical control and/or modification of oxygen therapy). A total of 17 patients compiled a usability questionnaire. The service was perceived as useful and well-structured, although it often required caregiver support.
Conclusions:
Using continuous home-monitoring care with an oxygen saturation device seems feasible and useful for patients who could be followed at home avoiding going back to the hospital every time a trend oximetry is needed. Further improvements in connections, data flow processes, and simplifications, based on patients' feedback, are needed to scale up the service.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...