Abstract:
Offset analgesia (OA) is observed when pain relief is disproportional to the reduction of noxious input and is based on temporal contrast enhancement (TCE). This phenomenon is believed to reflect the function of the inhibitory pain modulatory system. However, the mechanisms contributing to this phenomenon remain poorly understood, with previous research focusing primarily on painful stimuli and not generalizing to nonpainful stimuli. Therefore, the aim of this study was to investigate whether TCE can be induced by noxious as well as innocuous heat and cold stimuli. Asymptomatic subjects (n = 50) were recruited to participate in 2 consecutive experiments. In the first pilot study (n = 17), the parameters of noxious and innocuous heat and cold stimuli were investigated in order to implement them in the main study. In the second (main) experiment, subjects (n = 33) participated in TCE paradigms consisting of 4 different modalities, including noxious heat (NH), innocuous heat (IH), noxious cold (NC), and innocuous cold (IC). The intensity of the sensations of each thermal modality was assessed using an electronic visual analog scale. TCE was confirmed for NH (P < .001), NC (P = .034), and IC (P = .002). Conversely, TCE could not be shown for IH (P = 1.00). No significant correlation between TCE modalities was found (r < .3, P > .05). The results suggest that TCE can be induced by both painful and nonpainful thermal stimulation but not by innocuous warm temperature. The exact underlying mechanisms need to be clarified. However, among other potential mechanisms, this may be explained by a thermo-specific activation of C-fiber afferents by IH and of A-fiber afferents by IC, suggesting the involvement of A-fibers rather than C-fibers in TCE. More research is needed to confirm a peripheral influence. PERSPECTIVE: This psychophysical study presents the observation of temporal contrast enhancement during NH, NC, and innocuous cold stimuli but not during stimulation with innocuous warm temperatures in healthy volunteers. A better understanding of endogenous pain modulation mechanisms might be helpful in explaining the underlying aspects of pain disorders.
More Related Videos
Related Concept Videos
Thermosensation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...