Related Experiment Video
Updated: Jul 19, 2025

Bronchial Thermoplasty: A Novel Therapeutic Approach to Severe Asthma
Published on: November 4, 2010
Temperature Profile Measurement From Radiofrequency Nasal Airway Reshaping Device
Eric H Abello1,2, Theodore V Nguyen1, Katelyn K Dilley1
1Beckman Laser Institute and Medical Clinic, Irvine, California, USA.
Objective:
Nasal airway obstruction (NAO) is caused by various disorders including nasal valve collapse (NVC). A bipolar radiofrequency (RF) device (VivAer®, Aerin Medical, Sunnyvale, CA) has been used to treat NAO through RF heat generation to the upper lateral cartilage (ULC). The purpose of this study is to measure temperature elevations in nasal tissue, using infrared (IR) radiometry to map the spatial and temporal evolution of temperature.
Study Design:
Experimental and computational.
Methods:
Composite porcine nasal septum was harvested and sectioned (1 mm and 2 mm). The device was used to heat the cartilage in composite porcine septum. An IR camera (FLIR® ExaminIR, Teledyne, Wilsonville, OR) was used to image temperature on the back surface of the specimen. These data were incorporated into a heat transfer finite element model that also calculated tissue damage using Arrhenius rate process.
Results:
IR temperature imaging showed peak back surface temperatures of 49.57°C and 42.21°C in 1 and 2 mm thick septums respectively. Temperature maps were generated demonstrating the temporal and spatial evolution of temperature. A finite element model generated temperature profiles with respect to time and depth. Rate process models using Arrhenius coefficients showed 30% chondrocyte death at 1 mm depth after 18 s of RF treatment.
Conclusion:
The use of this device creates a thermal profile that may result in thermal injury to cartilage. Computational modeling suggests chondrocyte death extending as deep as 1.4 mm below the treatment surface. Further studies should be performed to improve dosimetry and optimize the heating process to reduce potential injury. Laryngoscope, 134:1063-1070, 2024.
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...