Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

7.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.1K
IR Spectrometers01:25

IR Spectrometers

1.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.2K
Chromatographic Resolution01:15

Chromatographic Resolution

525
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
525
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

57
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
57
IR Frequency Region: X–H Stretching01:24

IR Frequency Region: X–H Stretching

1.0K
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of  2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in...
1.0K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

724
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
724

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

30 dB on-chip ultra-high inverse weak value amplification.

Optics letters·2026
Same author

Revealing the fuel of a quantum continuous measurement-based refrigerator.

Physical review. E·2026
Same author

Quantum benchmarking of high-fidelity noise-biased operations on a detuned Kerr-cat qubit.

Proceedings of the National Academy of Sciences of the United States of America·2026
Same author

Encrypted Qubits Can Be Cloned.

Physical review letters·2026
Same author

Reconciling and validating the Ashworth-Davies Doppler shifts of an arbitrarily translating mirror.

Journal of the Optical Society of America. A, Optics, image science, and vision·2025
Same author

Exploring the Accuracy of Interferometric Quantum Measurements under Conservation Laws.

Physical review letters·2025
Same journal

Erratum: Bacterial Turbulence at Compressible Fluid Interfaces [Phys. Rev. Lett. 136, 138301 (2026)].

Physical review letters·2026
Same journal

Unveiling Light-Quark Yukawa Flavor Structure via Dihadron Fragmentation at Lepton Colliders.

Physical review letters·2026
Same journal

Adaptable Route to Fast Coherent State Transport via Bang-Bang-Bang Protocols.

Physical review letters·2026
Same journal

Topological Transition and Emergence of Elasticity of Dislocation in Skyrmion Lattice: Beyond Kittel's Magnetic-Polar Analogy.

Physical review letters·2026
Same journal

Pound-Drever-Hall Method for Superconducting-Qubit Readout.

Physical review letters·2026
Same journal

Coupling a ^{73}Ge Nuclear Spin to an Electrostatically Defined Quantum Dot in Silicon.

Physical review letters·2026
See all related articles

Related Experiment Video

Updated: Jul 19, 2025

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.4K

Super Interferometric Range Resolution.

John C Howell1,2, Andrew N Jordan1,3,4, Barbara Šoda5

  • 1Institute for Quantum Studies, Chapman University, Orange, California 92866, USA.

Physical Review Letters
|August 18, 2023
PubMed
Summary
This summary is machine-generated.

Researchers improved range resolution in coherent remote sensing using novel interference functions. This new method significantly enhances the ability to distinguish closely spaced objects, surpassing current limitations.

More Related Videos

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K
Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
11:57

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM

Published on: December 1, 2016

10.8K

Related Experiment Videos

Last Updated: Jul 19, 2025

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.4K
Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.5K
Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
11:57

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM

Published on: December 1, 2016

10.8K

Area of Science:

  • Physics
  • Electrical Engineering
  • Signal Processing

Background:

  • Coherent remote sensing relies on precise range resolution to distinguish targets.
  • Current methods face limitations in resolving closely spaced objects or depths.

Purpose of the Study:

  • To investigate and enhance the fundamental limits of range resolution in coherent remote sensing.
  • To introduce a novel approach using self-referential interference functions for improved depth discrimination.

Main Methods:

  • Utilized a novel class of self-referential interference functions.
  • Re-framed range resolution as single-parameter estimation of amplitude, diverging from traditional temporal resolution.
  • Defined new figures of merit for depth and distance resolution.

Main Results:

  • Demonstrated significant improvement over accepted bounds for range resolution.
  • Experimentally resolved two depths exceeding 100 times the inverse bandwidth.
  • Measured inter-object distance to approximately 20 micrometers for temporally subresolved objects.

Conclusions:

  • The novel self-referential interference approach offers superior range resolution capabilities.
  • This method pushes the boundaries of depth and distance measurement in coherent remote sensing.
  • The findings have implications for applications requiring high-resolution sensing with radio waves.