Related Experiment Video
Updated: Jun 16, 2026

Author Spotlight: Evaluating the Adjuvant Efficacy and Safety of Angong Niuhuang Pill in Viral Encephalitis Treatment
Published on: April 19, 2024
Increasing transparency in indirect treatment comparisons: is selecting effect modifiers the missing part of the
Andreas Freitag1, Laura Gurskyte2, Grammati Sarri3
1Cytel, Evidence Value & Access, London, WC2B 4HN, UK.
Abstract:
Failure to adjust for effect modifiers (EMs) in indirect treatment comparisons (ITCs) can produce biased and uncertain effect estimates. This is particularly important for health technology assessments (HTAs), where the availability of new treatments is based on comparative effectiveness results. Much emphasis has been placed on advancing ITC methods to adjust for EMs, yet whether EMs are appropriately identified for the conduct of ITCs in the first place is unclear. To understand the extent of guidance and requirements for the selection of EMs for ITCs currently available and if and how this guidance is applied in practice, a series of pragmatic reviews of guidance documents from HTA and non-payer organizations, primary published ITC analyses, and prior HTA submissions in two indications (non-small cell lung cancer and psoriasis) was conducted. The reviews showed that current ITC guidance mainly focused on developing analytical methods to adjust for EMs. Some organizations, such as HTA bodies in the UK, France and Germany, recommended the use of literature reviews, expert opinion and statistical methods to identify EMs. No detailed guidance on the selection process or the appropriate literature review approach was found. Similar trends were identified through the database search and review of prior HTA submissions; only few published ITCs and submissions included information on the EM selection process which was either based on findings from the literature, trial subgroup analyses, or clinical input. No reference to a systematic selection approach was found. There is an urgent need to fill the guidance gap identified across the reviews by including a step in ITC guidelines on how EMs should be identified through systematic reviews, formal expert elicitation, and a quantitative assessment of the EM distribution. Researchers and manufacturers are also encouraged to improve transparent reporting and justification of their selection of EMs to allow for an independent review of the set of factors being considered for adjustment. Both will contribute toward reducing bias in the ITC results and ultimately increase confidence in decision-making.
More Related Videos
06:55Inverse Probability of Treatment Weighting Propensity Score using the Military Health System Data Repository and National Death Index
Published on: January 8, 2020
07:25In Vitro Methods for Comparing Target Binding and CDC Induction Between Therapeutic Antibodies: Applications in Biosimilarity Analysis
Published on: May 4, 2017
Related Concept Videos
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs
Strategies for Assessing and Addressing Confounding
Confounding can be addressed at both the design phase of a study and through analytical methods after data...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast, controlled...
Blinding
Blind Procedures
Bias in Epidemiological Studies