Related Experiment Video
Updated: Jul 18, 2025

Measuring the Interaction Force Between a Droplet and a Super-hydrophobic Substrate by the Optical Lever Method
Published on: June 14, 2019
Characterization of solute-solvent interactions in liquid chromatography systems: A fast method based on Abraham's
Lídia Redón1, Mahmoud Safar Beiranvand1, Xavier Subirats1
1Institute of Biomedicine (IBUB) and Department of Chemical Engineering and Analytical Chemistry, Universitat de Barcelona, Martí i Franquès 1-11, 08028, Barcelona, Spain.
Abstract:
The Abraham's solvation parameter model, based on linear solvation energy relationships (LSER), allows the accurate characterization of the selectivity of chromatographic systems according to solute-solvent interactions (polarizability, dipolarity, hydrogen bonding, and cavity formation). However, this method, based on multilinear regression analysis, requires the measurement of the retention factors of a considerably high number of compounds, turning it into a time-consuming low throughput method. Simpler methods such as Tanaka's scheme are preferred. In the present work, the Abraham's model is revisited to develop a fast and reliable method, similar to the one proposed by Tanaka, for the characterization of columns employed in reversed-phase liquid chromatography and particularly in hydrophilic interaction liquid chromatography. For this purpose, pairs of compounds are carefully selected in order to have in common all molecular descriptors except for a specific one (for instance, similar molecular volume, dipolarity, polarizability, and hydrogen bonding basicity features, but different hydrogen bonding acidity). Thus, the selectivity factor of a single pair of test compounds can provide information regarding the extent of the dissimilar solute-solvent interactions and their influence on chromatographic retention. The proposed characterization method includes the determination of the column hold-up volume and Abraham's cavity term by means of the injection of four alkyl ketone homologues. Therefore, five chromatographic runs in a reversed-phase column (four pairs of test solutes and a mixture of four homologues) are enough to characterize the selectivity of a chromatographic system. Tanaka's method is also analyzed from the LSER point of view.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
09:42Unraveling Entropic Rate Acceleration Induced by Solvent Dynamics in Membrane Enzymes
Published on: January 16, 2016
Related Concept Videos
Entropy and Solvation
Solubility Equilibria: Overview
Solubility is important in biological and environmental processes. A notable...
Energetics of Solution Formation
When the strengths of the intermolecular forces of attraction between solute and solvent species in a solution are no different than those present in the separated components, the solution is formed with no accompanying energy change. Formation of the solution requires the solute–solute and solvent–solvent...
Chemical and Solubility Equilibria
Analyte Adsorption and Distribution
Ideal Solutions