Related Experiment Video
Updated: Jul 18, 2025

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Correlation of Ocular Plane-Wave Doppler With Optical Coherence Tomography Angiography in Preeclampsia
Ronald H Silverman1, Raksha Urs1, Ronald J Wapner2
1Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA.
Objectives:
Preeclampsia (PE) is a severe complication of pregnancy characterized by hypertension, proteinuria and compromised fetal blood supply. The eye, like other end organs, is affected by this systemic condition, but unlike in other organs, ocular media transparency allows high-resolution optical visualization of the vascular structure of the retina. Our aim was to assess how ultrasound-determined ocular blood-flow correlates with vascular structure of the retina and choriocapillaris determined by optical coherence tomography angiography (OCTA).
Methods:
Plane-wave ultrasound and OCTA were performed on both eyes of 40 consecutive subjects consisting of normal controls (n = 11), mild PE (n = 5), severe PE (n = 17) and chronic or gestational hypertension (n = 7) within 72 hours following delivery. From ultrasound, we measured pulsatile flow velocity and resistance indices in the central retinal artery (CRA) and vein, the short posterior ciliary arteries (SPCAs) and choroid. From OCTA, we measured vascular density (VD) in the superficial, deep retina and choriocapillaris. We determined differences in Doppler and OCTA parameters among groups and correlations between ultrasound and OCTA.
Results:
In severe PE, flow resistance was reduced with respect to controls. Flow velocity and resistance in the and SPCA were moderately correlated with VD in the choriocapillaris and peripapillary retina, but VD in PE did not differ significantly from controls.
Conclusions:
Although OCTA parameters were moderately correlated with Doppler ultrasound, OCTA did not demonstrate significant differences between PE and controls postpartum.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Glaucoma: Overview