Relation between characteristic temperature and elution temperature in temperature programmed gas chromatography -
Tillman Brehmer1, Peter Boeker2, Matthias Wüst1
1University of Bonn, Institute of Nutritional and Food Sciences, Chair of Food Chemistry - Department Fast GC, Endenicher Allee 11 - 13, 53115 Bonn, Germany.
Abstract:
The development of new analytical methods can save resources, time and costs if there are prediction tools like computer simulation which support the optimization process. In GC the distribution-centric 3-parameter model (K-centric model) is well established for prediction of retention factors k and retention times but laborious isothermal measurements for determination of the characteristic parameters are needed. For the most important parameter, the characteristic temperature Tchar, the search for simpler determination methods or even estimates is an interesting research topic. In this work the elution temperatures for 37 fatty acid methyl esters, 6 BTEXs and 40 other volatile substances are determined by measurements under variable heating rates, initial temperatures, constant pressure mode and constant flow mode. The relationship between the measured elution temperature and the characteristic temperature was investigated. The novel multivariate curve fit model presented in this study describes accurately the relation between the characteristic temperature Tchar and elution temperatures Telu under variable heating rates RT, respectively, and initial temperature Tinit conditions. The novel model shows good accordance to earlier estimation models and expands the prediction range, especially for high volatile compounds. The model is suitable for determination of Tchar by estimated Telu and vice versa. Predictions of retention times of simple temperature programs were also possible by using the model with relative deviations < 5% compared to measurements.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:15Metabolomic Analysis of Barley by Gas Chromatography/Mass Spectrometry
Published on: November 8, 2024
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Le Chatelier's Principle: Changing Temperature
To understand this phenomenon, consider the elementary reaction: