Assessing the connection between competitive industrial performance on load capacity factor within the LCC framework:

Abdullah Emre Caglar1, Muhammet Daştan2, Usman Mehmood3,4

  • 1Department of Statistics, Ataturk University, Erzurum, Turkey. aecaglar@atauni.edu.tr.

Related Concept Videos

Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
138
Factors Affecting Activity Coefficient01:17

Factors Affecting Activity Coefficient

The extended Debye-Hückel equation indicates that the activity coefficient of an ion in an aqueous solution at 25°C depends on three partially interdependent properties: the ionic strength of the solution, the charge of the ion, and the ion size. 
The activity coefficient value for an ion is close to one when the solution has almost zero ionic strength, i.e., when the solution shows close to ideal behavior. As the ionic strength of the solution increases from 0 to 0.1 mol/L, a...
832
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
191
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
203
Relation Between the Distributed Load and Shear01:23

Relation Between the Distributed Load and Shear

Understanding the relationship between the distributed load and shear force in structural analysis is crucial for analyzing beams subjected to various loading conditions. Consider the case of a beam experiencing a distributed load, two concentrated loads, and a couple moment.
670
Production Efficiency01:01

Production Efficiency

Net production efficiency (NPE) is the efficiency at which organisms assimilate energy into biomass for the next trophic level. Due to low metabolic rates and less energy spent on thermoregulatory processes, the NPE of ectotherms (cold-blooded animals) is 10 times higher than endotherms (warm-blooded animals).
16.9K