Related Experiment Video
Updated: Jul 18, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Fibular Autograft as Medial Support with Proximal Humerus Locking Plate Construct in Comminuted Proximal Humerus
Sameer Panchal1, Sangeet Gawhale2, Amit Kumar Yadav1
1Department of Orthopaedics, Sir HN Reliance Foundation Hospital and Research Centre, Mumbai, 400004 India.
Background:
Varus collapse is one of the pivotal mechanisms of failure following surgical fixation of proximal humerus fractures. The aim of the present study was to evaluate functional and radiological outcomes of non-vascularized fibular autograft as medial support with locking plate construct for comminuted proximal humerus fractures (PHF's).
Materials And Methods:
We retrospectively evaluated 18 patients with unstable PHF's in the age group 50-70 years with a minimum follow-up of two years. All the fracture patterns were classified according to Resch, Neer's and AO classification and either medial calcar compromise or comminution were present in all. Open reduction internal fixation (ORIF) with a locking plate was performed for all the patients along with intramedullary fibular autograft to support medial calcar. Radiological outcome was assessed by neck-shaft angle (NSA) graded according to the Paavolainen grading method and difference in the humeral head height (HHH). Functional outcome was assessed by shoulder range of motion (ROM), University of California-Los Angeles (UCLA) score and American shoulder and elbow surgeons score (ASES).
Results:
Radiological union at the fracture site was achieved in all the patients at mean of 8 months (range 6-12 months). Range of movements were mean flexion of 123.89, extension 35.28, internal rotation 66.94, external rotation 57.78 and abduction of 115° at final follow-up. The average NSA was in the range of 120°-130° and none of the patients showed difference in HHH of ≥ 4 mm in the immediate post-operative radiograph and that taken on final follow-up. The functional outcome assessed by ASES score (mean 89.44) and UCLA score (mean 29.61) suggested fair to good results. None of the patients has shown varus collapse and avascular necrosis. Neither there were any complications related to the donor area.
Conclusions:
In unstable proximal humerus fractures with calcar comminution or void, PHILOS plate fixation augmented with fibular autograft as a medial support reduces varus collapse and promotes early radiological union.
More Related Videos
Related Concept Videos
Bones of the Upper Limb: Humerus
Bones of the Upper Limb: Ulna
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Lower Limb: Tibia and Fibula