Examination of resistance of various methods of pulmonary vessel occlusion to hydrostatic pressure
Related Experiment Video
Updated: Jul 18, 2025

Assessing Murine Resistance Artery Function Using Pressure Myography
Published on: June 7, 2013
Darko Gajić1, Małgorzata Wojtyś1, Norbert Wójcik1
1Department of Thoracic Surgery and Transplantation, Pomeranian Medical University, Alfreda Sokołowskiego 11, 70-891 Szczecin, Poland.
Objective:
The aim of this study was to compare pressure resistance of the most common methods of vessel occlusion during thoracic surgical procedures: ligations, clips, and vascular endostaplers.
Methods:
Pulmonary vessels were obtained during routine thoracic surgeries. A ball-tipped cannula was inserted through an opening in the side wall and secured with a linen ligature from slipping out. Subsequently, saline was infused into the vessel. We recorded the pressure on which a leakage occurred.
Results:
A total of 65 vessels, divided between 3 groups, were enrolled in the study. In the endostaplers group, median bursting pressures were 262.5 mmHg and 300 mmHg for arteries and veins, respectively. In the case of clips, it was over 750 mmHg in both types of the vessels. The same results were observed in the ligation group. Minimal bursting pressures in endostapler occlusion were 187.5 mmHg and 225 mmHg in arteries and veins, respectively. In the case of clips, it was 600 mmHg for arteries and 675 mmHg for veins. A total of 525 mmHg (arteries) and 750 mmHg (veins) were the minimal leaking values observed in vessels occluded with ligations. Comparative analysis showed statistically significant differences in endostapler-clips and endostapler-ligations pairs (p < 0.001). There were no differences between clips and ligations.
Conclusions:
The examined methods are capable of occluding pulmonary vessels under physiological conditions. Furthermore, ligations and clips are resistant to pressures highly exceeding physiological values.
More Related Videos
13:32Videomorphometric Analysis of Hypoxic Pulmonary Vasoconstriction of Intra-pulmonary Arteries Using Murine Precision Cut Lung Slices
Published on: January 14, 2014
09:23Shunt Surgery, Right Heart Catheterization, and Vascular Morphometry in a Rat Model for Flow-induced Pulmonary Arterial Hypertension
Published on: February 11, 2017
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Assessment of blood pressure in brachial artery(two-step method)