Related Experiment Video
Updated: Jul 18, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Controlling the positive ion electrospray ionization of poly(ethylene glycols) when using ultra-high-performance
Sergio Cancho-Gonzalez1, Paul Ferguson2, Julie M Herniman1
1Faculty of Engineering & Physical Sciences, School of Chemistry, University of Southampton, Southampton, UK.
Abstract:
Poly(ethylene glycols) are complex polymers often added to pharmaceutical formulations to improve drug solubility and delivery. One of the main challenges when using chromatographic techniques coupled to mass spectrometry is the unselective ionization of poly(ethylene glycols) oligomers. Additionally, when the chain length is large enough, multiple charged species are formed, further complicating the mass spectra and processing. This study uses the advanced oligomer separation provided by supercritical fluid chromatography with a mass spectrometry approach that selectively ionizes poly(ethylene glycols) as ammoniated molecules to simplify data analysis and facilitate batch-to-batch comparisons. Several visual representations of the response of the ionization events based on the polymer molecular weight and the repeating unit were used to elucidate trends in ionization. Evaluation of the influence of the oligomer length and end-group on the electrospray ionization of the polymer allowed the development of a process to enable selective ionization for these complex polymers.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...