Background:
Fibrotic atrial cardiomyopathy plays an important role in determining the outcome of ablation in patients with atrial fibrillation (AF). Two main methods are being used for the evaluation of fibrosis: voltage-based high-density (HD) electroanatomical mapping (EAM) and late gadolinium enhancement MRI (LGE-MRI). The comparability between both methods in detecting fibrosis has not been systematically investigated.
Methods:
LGE-MRIs of the left atrium (LA) were performed in 21 patients. LA-fibrosis was evaluated using a custom-designed software generating a 3D-model of the LA. HD-electroanatomical maps were recorded in each patient. After processing the maps and the MRI models by excluding the mitral valve, pulmonary veins, and the left atrial appendage, the LGE areas were measured and compared to the low voltage areas (LVA) in the HD maps using three different cutoff values of 0.5 mV, 0.7 mV, and 1.0 mV.
Results:
The analysis revealed significant differences between EAM and LGE-MRI in assessing LA-fibrosis at 0.5-mV (for anterior and posterior walls) and 1.0-mV cutoffs (for anterior and posterior wall and septum). However, no significant differences were found between EAM and LGE-MRI when using a 0.7-mV cutoff for all the investigated areas.
Conclusions:
A voltage cutoff of 0.7 mV provided the best correlation between EAM and LGE MRI for detecting left atrial fibrosis. It supports the idea that a 0.5-mV cutoff may underestimate fibrosis, as areas with local signal voltages between 0.6 and 0.8 mV could also show LGE on MRI. Further research is needed to determine the ideal voltage cutoff for detecting left atrial fibrosis.
More Related Videos
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
07:38A Multimodal Imaging Approach Based on Micro-CT and Fluorescence Molecular Tomography for Longitudinal Assessment of Bleomycin-Induced Lung Fibrosis in Mice
Published on: April 13, 2018
Related Concept Videos
Magnetic Resonance Imaging
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):