Multisample Ultrasound Point Shear Wave Elastography of the Liver: Repeatability and Agreement With Conventional
Jonathan R Dillman1, Andrew T Trout1
1Department of Radiology, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, Ohio, USA.
Objective:
To characterize the technical performance of a multisample ultrasound point shear wave elastography (pSWE) technique that allows 15 individual measurements of liver stiffness in a single acquisition.
Methods:
In 56 overweight and obese adults, research ultrasound examinations were performed using conventional pSWE and multisample pSWE (Sequoia; Siemens Healthineers). Five independent measurements were acquired with the conventional technique over five consecutive breath holds (5C1 and DAX transducers). A single multisample acquisition (DAX transducer) of up to 15 unique measurements was acquired during a single breath hold. All imaging was performed before (baseline) and after a "coffee break" (repeat). Median liver stiffness measurements between techniques and between baseline and repeat imaging were compared using Pearson correlation (r) and intra-class correlation (ICC) coefficients.
Results:
Mean participant age was 33.7 ± 11.4 years; 40 participants were female. There was high correlation between conventional pSWE measurements obtained using the 5C1 and DAX transducers at baseline (r = .75 [95% CI: 0.61-0.85], P < .0001) and repeat (r = .88 [95% CI: 0.78-0.92], P < .0001). There was moderate agreement between conventional pSWE measurements obtained using the 5C1 and DAX transducers at baseline (ICC = 0.69 [95% CI: 0.52-0.81]), and good agreement at repeat (ICC = 0.81 [95% CI: 0.65-0.90]). There was moderate correlation (r = .59 [95% CI: 0.39-0.74], P < .0001) and moderate agreement (ICC = 0.58 [95% CI: 0.38-0.73]) between baseline conventional and multisample pSWE measurements acquired using the DAX transducer; there was high correlation (r = .73 [95% CI: 0.57-0.83], P < .0001) and moderate agreement (ICC = 0.72 [95% CI: 0.56-0.82] between techniques at repeat. There was moderate correlation (r = .65 [95% CI: 0.46-0.78], P < .0001) and moderate agreement (ICC = 0.64 [95% CI: 0.45-0.77]) between baseline and repeat multisample pSWE measurements.
Conclusions:
Multisample pSWE, allowing up to 15 measurements in a single breath hold, showed moderate to high correlation and moderate agreement with conventional pSWE.
More Related Videos
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography