Related Experiment Video
Updated: Jul 18, 2025

Combined Supine and Standing Imaging for Varicocele: An Improved Diagnostic Approach
Published on: November 22, 2024
A novel approach for screening standard anteroposterior pelvic radiographs in children
Jia Sha1, Luyu Huang1, Yaopeng Chen2
1Department of Orthopedics, Xijing Hospital, Air Force Medical University, No.15 Changle Xi Road, Xi'an, 710032, China.
Abstract:
Anteroposterior pelvic radiography is the first-line imaging modality for diagnosing developmental dysplasia of the hip (DDH). Nonstandard radiographs with pelvic malposition make the correct diagnosis of DDH challenging. However, as the only method available for screening standard pelvic radiographs, traditional manual assessment is relatively laborious and potentially erroneous. We retrospectively collected 3,247 pelvic radiographs. There were 2,887 radiographs randomly selected to train and optimize the AI model. Then 362 radiographs were used to test the model's diagnostic performance. Its diagnostic accuracy was assessed using receiver operating characteristic (ROC) curves and measurement consistency using Bland-Altman plots. In 362 radiographs, the AI model's area under ROC curves, accuracy, sensitivity, and specificity for quality assessment was 0.993, 99.4% (360/362), 98.6% (138/140), and 100.0% (222/222), respectively. Compared with clinicians, the 95% limits of agreement (Bland-Altman analysis) for pelvic tilt index (PTI) and pelvic rotation index (PRI), as determined by the model, were -0.052-0.072 and -0.088-0.055, respectively.
Conclusions:
The artificial intelligence-assisted method was more efficient and highly consistent with clinical experts. This method can be used for real-time validation of the quality of pelvic radiographs in current picture archiving and communications systems (PACS).
What Is Known:
• Nonstandard pediatric radiographs with pelvic malposition make the correct diagnosis of developmental dysplasia of the hip (DDH) challenging. • Traditional manual assessment remains the only method available for screening standard pediatric pelvic radiographs, which is relatively laborious and potentially erroneous.
What Is New:
• This study proposed an artificial intelligence-assisted model to assess the quality of pediatric pelvic radiographs accurately and efficiently. • We recommend the integration of the model into current picture archiving and communications systems (PACS) for real-time screening of standard pediatric pelvic radiographs.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Radiological Investigation I: X-ray and CT
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Imaging Studies I: Kidney, Ureter, and Bladder Studies