Related Experiment Video
Updated: Jul 18, 2025

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Electroanatomical voltage mapping with contact force sensing for diagnosis of arrhythmogenic right ventricular
A M Saguner1, D Lunk2, M Mohsen3
1Arrhythmia Division, Department of Cardiology, University Heart Center Zurich, University Hospital Zurich, Zurich, Switzerland; Center for Translational and Experimental Cardiology (CTEC), Department of Cardiology, Zurich University Hospital, University of Zurich, 8952 Schlieren, Switzerland.
Background:
Three-dimensional electroanatomical mapping (EAM) can be helpful to diagnose arrhythmogenic right ventricular cardiomyopathy (ARVC). Yet, previous studies utilizing EAM have not systematically used contact-force sensing catheters (CFSC) to characterize the substrate in ARVC, which is the current gold standard to assure adequate tissue contact.
Objective:
To investigate reference values for endocardial right ventricular (RV) EAM as well as substrate characterization in patients with ARVC by using CFSC.
Methods:
Endocardial RV EAM during sinus rhythm was performed with CFSC in 12 patients with definite ARVC and 5 matched controls without structural heart disease. A subanalysis for the RV outflow tract (RVOT), septum, free-wall, subtricuspid region, and apex was performed. Endocardial bipolar and unipolar voltage amplitudes (BVA, UVA), signal characteristics and duration as well as the impact of catheter orientation on endocardial signals were also investigated.
Results:
ARVC patients showed lower BVA vs. controls (p = 0.018), particularly in the subtricuspid region (1.4, IQR:0.5-3.1 vs. 3.8, IQR:2.5-5 mV, p = 0.037) and RV apex (2.5, IQR:1.5-4 vs. 4.3,IQR:2.9-6.1 mV, p = 0.019). BVA in all RV regions yielded a high sensitivity and specificity for ARVC diagnosis (AUC 59-78%, p < 0.05 for all), with the highest performance for the subtricuspid region (AUC 78%, 95% CI:0.75-0.81, p < 0.001, negative predictive value 100%). A positive correlation between BVA and an orthogonal catheter orientation (46°-90°:r = 0.106, p < 0.001), and a negative correlation between BVA and EGM duration (r = -0.370, p < 0.001) was found.
Conclusions:
EAM using CFSC validates previous bipolar cut-off values for normal endocardial RV voltage amplitudes. RV voltages are generally lower in ARVC as compared to controls, with the subtricuspid area being commonly affected and having the highest discriminatory power to differentiate between ARVC and healthy controls. Therefore, EAM using CFSC constitutes a promising tool for diagnosis of ARVC.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019