Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Dynamic cord compression induced by proximal junctional failure and loose pedicle screws after thoracolumbar fusion
Takahiro Kozaki1, Takuhei Kozaki2,3, Keiji Nagata1
1Department of Orthopaedic Surgery, Wakayama Medical University, 811-1 Kimiidera, Wakayama, 641-0012, Japan.
Background:
One of the common mechanical complications following spinal fusion surgery is proximal junctional failure (PJF). The incidence of neurological deficit associated with PJF has been poorly described in the literature. Here, we report a case in which numbness in the lower extremities was recognized as the first symptom, but the discrepancy in the imaging findings made PJF difficult to diagnose.
Methods:
A 71-year-old female underwent corrective fusion surgery. Three weeks later, she complained of persistent right leg numbness. Standing X-ray showed the back-out of the pedicle screws (PSs) in the upper instrumented vertebra (UIV), but there was no obvious evidence of cord compression on computed tomography (CT), which caused the delay of diagnosis. Five weeks later, magnetic resonance image (MRI) did not show cord compression on an axial view, but there were signal changes in the spinal cord.
Results:
The first reason for the delayed diagnosis was the lack of awareness that leg numbness could occur as the first symptom of PJF. The second problem was the lack of evidence for spinal cord compression in various imaging tests. Loosened PSs were dislocated on standing, but were back to their original position on supine position. In our case, these contradictory images led to a delay in diagnosis.
Conclusion:
Loosened PSs caused dynamic cord compression due to repeated deviation and reduction. Supine and standing radiographs may be an important tool in the diagnosis of PJF induced by dynamic cord compression.