Systematic review: Validity, reliability, and diagnostic accuracy of the electrogustometer
Esther E Blijleven1,2, Denise Fuchten1,2, Max J Dullaart1
1Department of Otorhinolaryngology-Head and Neck Surgery University Medical Center Utrecht Utrecht The Netherlands.
Laryngoscope Investigative Otolaryngology
|August 25, 2023
Summary
The electrogustometer (EGM) shows good test-retest reliability but weak validity for assessing taste sensation. Current evidence does not support its use as a clinical screening tool for taste disturbances.
Area of Science:
- Otorhinolaryngology
- Neuroscience
- Sensory Science
Background:
- Assessing taste sensation is crucial for diagnosing various medical conditions.
- The electrogustometer (EGM) is a device used to measure taste function.
- Understanding the psychometric properties of the EGM is essential for its clinical application.
Purpose of the Study:
- To systematically evaluate the validity, reliability, and diagnostic accuracy of the electrogustometer (EGM) in assessing taste sensation in adults.
- To compare the EGM's performance against established taste testing methods.
Main Methods:
- A systematic literature search was conducted on December 20, 2022, across PubMed, Embase, and Cochrane Library databases.
- Included were randomized controlled trials and observational studies with original data involving adults undergoing electrogustometry.
- Studies were excluded if they lacked analysis of validity, reliability, or diagnostic accuracy.
Main Results:
- Nineteen articles from 18 studies were analyzed, with a high risk of bias noted.
- The association between EGM and reference taste tests was generally moderate to weak (correlation coefficients -0.51 to 0.40).
- Test-retest reliability was good (0.78-1.0), but diagnostic accuracy metrics (sensitivity, specificity, PPV, NPV) varied widely.
Conclusions:
- The included studies lack sufficient methodological rigor to establish the EGM's validity, reliability, and diagnostic accuracy.
- Further high-quality research is required to validate the EGM's measurement properties.
- The EGM is not recommended as a screening tool for taste disturbances in clinical practice due to current evidence limitations.
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
42
Dysrhythmias, also known as arrhythmias, are disturbances in the heart's rhythm that range from benign to life-threatening. A thorough evaluation is crucial for appropriate management and involves a comprehensive medical history, physical examination, and various diagnostic tests.Medical HistorySymptoms: Collect detailed information on palpitations, dizziness, syncope, chest pain, and fatigue. Note their onset, frequency, and triggers.Previous Cardiac Issues: Document any history of heart...
42
Voltmeter
1.6K
A voltmeter is an electrical device that measures the potential difference or voltage between two points. It is connected in parallel with the circuit element it is measuring. A parallel connection is used because elements in parallel experience the same potential difference. The voltmeter is represented by the symbol "V ".
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have...
An ideal voltmeter would have infinite resistance, so connecting it between two points in a circuit would not alter any of the currents. Real voltmeters always have...
1.6K
Electrogravimetric Analysis: Overview
271
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
271
Electrodes: Overview
1.7K
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
1.7K
Electrocardiogram
2.5K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
2.5K
Amperometry: Overview
603
Amperometry is a technique commonly used to measure the concentration of specific analytes in a solution by monitoring the electric current generated during an electrochemical reaction. It involves applying a constant potential between a working electrode and a reference electrode to measure the resulting current, which is proportional to the concentration of the analyte. The Clark oxygen electrode operates based on this principle of amperometry. It consists of a cathode and an anode enclosed...
603