Related Experiment Video
Updated: Jul 18, 2025

Mimicking and Measuring Occlusal Erosive Tooth Wear with the "Rub&Roll" and Non-contact Profilometry
Published on: February 2, 2018
Evaluation of the Pulp Chamber Temperature during Tooth Veneer Preparation Using Burs with Different Degrees of
Edmond Ciora1,2, Mariana Miron1,3, Daliana Bojoga1,3
1Department of Oral Rehabilitation and Dental Emergencies, Faculty of Dentistry, "Victor Babes" University of Medicine and Pharmacy, P-ta Eftimie Murgu 2, 300041 Timisoara, Romania.
Abstract:
The heat produced during tooth preparation could be a source of damage for dental pulp, and many variables are involved in this process. The aim of this in vitro study was to evaluate whether the different degrees of wear of the diamond burs significantly influenced the temperature changes in the pulp chamber during tangential veneer preparation. The sample comprised 30 intact permanent monoradicular teeth, randomly assigned to three study groups of 10 teeth each, of which 5 had the pulp tissue preserved and 5 had thermoconductive paste in the pulp chamber. For prosthetic preparation, we used new burs in the first group, burs at their fifth use in the second group, and burs at their eighth use for the third group. The pulp chamber temperature was evaluated at the start, after one minute, and after three minutes of preparation, using a k-type thermocouple. The results of the three-way ANOVA and Tukey post hoc comparisons showed a highly significant effect of the time of measurement, while the pulp condition and the degree of wear of the burs had no effect. In conclusion, the different degrees of wear of conventional diamond burs do not produce statistically significant different changes in the pulp chamber temperature.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
06:16Author Spotlight: Establishing an Accurate Microhardness Testing Protocol for Craniofacial Tissues
Published on: April 26, 2024
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Veneer
Other veneering techniques include plain-slicing, quarter-slicing, and rift-slicing. These...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.