Rémy Mailli1, Olivier Chevallier1,2, Amin Mazit1
1Department of Vascular and Interventional Radiology, Image-Guided Therapy Center, Francois-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France.
Abstract:
The Micro Vascular Plug® (MVP, Medtronic) is a mechanical embolic agent available in small sizes that allows for distal embolisation. The objective of this retrospective observational single-centre study was to assess MVP embolisation procedures performed at a university hospital. The 33 patients who underwent MVP embolisation in 2021 were included (mean age, 64; 24 males and 9 females). The primary endpoint was technical success, which was defined as a full first-attempt occlusion with one or more MVPs, as documented on the end-of-procedure angiogram. In all patients, 51 MVPs were used overall, with other embolic agents in 23 of the 33 cases (usually coils and/or glue); 22 of the 33 procedures were emergent for bleeding and 11 were planned for other indications. Of the three technical failures, two were due to an angled target artery configuration precluding microcatheterisation and one to failure of the device to release from its wire. The technical success rate was thus 90.9%. No patient experienced MVP migration or other major complications. Five patients had recurrent clinical symptoms; in four cases, the cause was collateral development, and in one case, the cause was incomplete initial embolisation. No instances of recanalisation were documented during the short follow-up of 12 months, for a 100% secondary clinical success rate. At our tertiary-level centre, the MVP was both effective and safe for peripheral applications. Interventional radiologists should be conversant with the techniques and indications of MVP embolisation.
Insights
The Micro Vascular Plug (MVP) demonstrated high technical success (90.9%) and a 100% secondary clinical success rate in peripheral embolisation procedures. This safe and effective device is suitable for interventional radiologists.
Area of Science:
- Vascular Surgery
- Interventional Radiology
- Medical Devices
Background:
- The Micro Vascular Plug (MVP) is a mechanical embolic agent designed for distal embolisation.
- Its efficacy and safety in clinical practice require further evaluation.
Purpose of the Study:
- To assess the outcomes of Micro Vascular Plug (MVP) embolisation procedures at a university hospital.
- To evaluate the technical success, safety, and clinical efficacy of the MVP device.
Main Methods:
- Retrospective observational single-centre study including 33 patients who underwent MVP embolisation in 2021.
- Primary endpoint: technical success defined as full first-attempt occlusion.
- Secondary endpoints: MVP migration, major complications, recurrent symptoms, and recanalisation.
Main Results:
- Technical success rate was 90.9% (30 out of 33 procedures).
- No instances of MVP migration or major complications were reported.
- 100% secondary clinical success rate at 12-month follow-up, with recurrent symptoms attributed to collateral development or incomplete embolisation.
Conclusions:
- The Micro Vascular Plug (MVP) is an effective and safe device for peripheral embolisation applications.
- Interventional radiologists should be familiar with MVP embolisation techniques and indications.
More Related Videos
10:50Osmotic Drug Delivery to Ischemic Hindlimbs and Perfusion of Vasculature with Microfil for Micro-Computed Tomography Imaging
Published on: June 29, 2013
11:49Autologous Endothelial Progenitor Cell-Seeding Technology and Biocompatibility Testing For Cardiovascular Devices in Large Animal Model
Published on: September 9, 2011