Related Experiment Video
Updated: Jul 18, 2025

Photoselective Vaporesection of the Prostate via an End-firing Lithium Triborate Crystal Laser
Published on: May 9, 2018
The Impact of Prostate Volume on the Prostate Imaging and Reporting Data System (PI-RADS) in a Real-World Setting
Yannic Volz1, Maria Apfelbeck1, Nikolaos Pyrgidis1
1Department of Urology, LMU Klinikum, Ludwig-Maximilians University, Marchioninistr. 15, 81377 Munich, Germany.
Abstract:
Multiparametric magnetic resonance imaging (mpMRI) has emerged as a new cornerstone in the diagnostic pathway of prostate cancer. However, mpMRI is not devoid of factors influencing its detection rate of clinically significant prostate cancer (csPCa). Amongst others, prostate volume has been demonstrated to influence the detection rates of csPCa. Particularly, increasing volume has been linked to a reduced cancer detection rate. However, information about the linkage between PI-RADS, prostate volume and detection rate is relatively sparse. Therefore, the current study aims to assess the association between prostate volume, PI-RADS score and detection rate of csP-Ca, representing daily practice and contemporary mpMRI expertise. Thus, 1039 consecutive patients with 1151 PI-RADS targets, who underwent mpMRI-guided prostate biopsy at our tertiary referral center, were included. Prior mpMRI had been assessed by a plethora of 111 radiology offices, including academic centers and private practices. mpMRI was not secondarily reviewed in house before biopsy. mpMRI-targeted biopsy was performed by a small group of a total of ten urologists, who had performed at least 100 previous biopsies. Using ROC analysis, we defined cut-off values of prostate volume for each PI-RADS score, where the detection rate drops significantly. For PI-RADS 4 lesions, we found a volume > 61.5 ccm significantly reduced the cancer detection rate (OR 0.24; 95% CI 0.16-0.38; p < 0.001). For PI-RADS 5 lesions, we found a volume > 51.5 ccm to significantly reduce the cancer detection rate (OR 0.39; 95% CI 0.25-0.62; p < 0.001). For PI-RADS 3 lesions, none of the evaluated clinical parameters had a significant impact on the detection rate of csPCa. In conclusion, we show that enlarged prostate volume represents a major limitation in the daily practice of mpMRI-targeted biopsy. This study is the first to define exact cut-off values of prostate volume to significantly impair the validity of PI-RADS assessed in a real-world setting. Therefore, the results of mpMRI-targeted biopsy should be interpreted carefully, especially in patients with prostate volumes above our defined thresholds.
Insights
Large prostate volume significantly reduces cancer detection rates in multiparametric MRI (mpMRI)-guided biopsies, especially for PI-RADS 4 and 5 lesions. Clinically significant prostate cancer detection is less reliable when prostate volumes exceed specific thresholds.
Area of Science:
- Urology
- Radiology
- Oncology
Background:
- Multiparametric magnetic resonance imaging (mpMRI) is crucial for diagnosing prostate cancer.
- Prostate volume can influence the detection rate of clinically significant prostate cancer (csPCa) on mpMRI.
- The relationship between PI-RADS score, prostate volume, and csPCa detection requires further clarification.
Purpose of the Study:
- To assess the association between prostate volume, PI-RADS score, and csPCa detection rates in a real-world setting.
- To define specific prostate volume cut-off values that significantly impair mpMRI-targeted biopsy validity.
Main Methods:
- Retrospective analysis of 1039 consecutive patients undergoing mpMRI-guided prostate biopsy.
- Inclusion of 1151 PI-RADS targets assessed by various radiology offices.
- ROC analysis to determine prostate volume cut-off values for PI-RADS 3, 4, and 5 lesions.
Main Results:
- For PI-RADS 4 lesions, prostate volumes > 61.5 ccm significantly reduced csPCa detection (OR 0.24).
- For PI-RADS 5 lesions, prostate volumes > 51.5 ccm significantly reduced csPCa detection (OR 0.39).
- No significant impact of prostate volume on csPCa detection was found for PI-RADS 3 lesions.
Conclusions:
- Enlarged prostate volume is a significant limitation in daily practice for mpMRI-targeted prostate biopsies.
- This study provides the first exact prostate volume thresholds impacting PI-RADS validity in real-world settings.
- mpMRI-targeted biopsy results require careful interpretation in patients with prostate volumes exceeding defined thresholds.
More Related Videos
Related Concept Videos
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies IV: Magnetic Resonance Imaging