Related Experiment Video
Updated: Jul 18, 2025

A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis ALS
Published on: February 21, 2011
Automatic Detection System for Velopharyngeal Insufficiency Based on Acoustic Signals from Nasal and Oral Channels
Yu Zhang1, Jing Zhang1, Wen Li1
1College of Biomedical Engineering, Sichuan University, Chengdu 610065, China.
Abstract:
Velopharyngeal insufficiency (VPI) is a type of pharyngeal function dysfunction that causes speech impairment and swallowing disorder. Speech therapists play a key role on the diagnosis and treatment of speech disorders. However, there is a worldwide shortage of experienced speech therapists. Artificial intelligence-based computer-aided diagnosing technology could be a solution for this. This paper proposes an automatic system for VPI detection at the subject level. It is a non-invasive and convenient approach for VPI diagnosis. Based on the principle of impaired articulation of VPI patients, nasal- and oral-channel acoustic signals are collected as raw data. The system integrates the symptom discriminant results at the phoneme level. For consonants, relative prominent frequency description and relative frequency distribution features are proposed to discriminate nasal air emission caused by VPI. For hypernasality-sensitive vowels, a cross-attention residual Siamese network (CARS-Net) is proposed to perform automatic VPI/non-VPI classification at the phoneme level. CARS-Net embeds a cross-attention module between the two branches to improve the VPI/non-VPI classification model for vowels. We validate the proposed system on a self-built dataset, and the accuracy reaches 98.52%. This provides possibilities for implementing automatic VPI diagnosis.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: