Related Experiment Video
Updated: Jul 18, 2025

Anaerobic Protein Purification and Kinetic Analysis via Oxygen Electrode for Studying DesB Dioxygenase Activity and Inhibition
Published on: October 3, 2018
Determination of Kinetic Parameters and Identification of the Rate-Determining Steps in the Oxygen Exchange Process
Natalia Porotnikova1, Dmitriy Zakharov1, Anna Khodimchuk1,2
1Laboratory of Kinetics, The Institute of High-Temperature Electrochemistry of the Ural Branch of the Russian Academy of Sciences, 20 Akademicheskaya Street, Yekaterinburg 620137, Russia.
Abstract:
The mixed ionic and electronic oxide LaNi0.6Fe0.4O3- (LNF) is a promising ceramic cathode material for solid oxide fuel cells. Since the reaction rate of oxygen interaction with the cathode material is extremely important, the present work considers the oxygen exchange mechanism between O2 and LNF oxide. The kinetic dependence of the oxygen/oxide interaction has been determined by two isotopic methods using 18O-labelled oxygen. The application of the isotope exchange with the gas phase equilibrium (IE-GPE) and the pulsed isotope exchange (PIE) has provided information over a wide range of temperatures (350-800 °C) and oxygen pressures (10-200 mbar), as each method has different applicability limits. Applying mathematical models to treat the kinetic relationships, the oxygen exchange rate (r, atom × cm-2 × s-1) and the diffusion coefficient (D, cm2/s) were calculated. The values of r and D depend on both temperature and oxygen pressure. The activation energy of the surface exchange rate is 0.73 ± 0.05 eV for the PIE method at 200 mbar, and 0.48 ± 0.02 eV for the IE-GPE method at 10-20 mbar; for the diffusion coefficient, the activation energy equals 0.62 ± 0.01 eV at 10-20 mbar for the IE-GPE method. Differences in the mechanism of oxygen exchange and diffusion on dense and powder samples are observed due to the different microstructure and surface morphology of the samples. The influence of oxygen pressure on the ratio of contributions of different exchange types to the total oxygen exchange rate is demonstrated. For the first time, the rate-determining step in the oxygen exchange process for LNF material has been identified. This paper discusses the reasons for the difference in the mechanisms of oxygen exchange and diffusion.
More Related Videos
Related Concept Videos
Multi-Step Reactions
Determination of Michaelis Constant and Maximum Elimination Rate
These parameters can be estimated by analyzing plasma concentration data post-drug administration. A notable example of this application is phenytoin, a drug with capacity-limited kinetics. It's recommended that phenytoin should be administered at two...
Measuring Reaction Rates
Calculating Equilibrium Concentrations
A more...