Related Experiment Video
Updated: Jul 18, 2025

Advanced Self-Healing Asphalt Reinforced by Graphene Structures: An Atomistic Insight
Published on: May 31, 2022
Modification and Enhancing Contribution of Fiber to Asphalt Binders and Their Corresponding Mixtures: A Study of
Chao Li1, Hao Liu2, Yue Xiao1,3
1School of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070, China.
Abstract:
The performance of asphalt binders and asphalt mixtures can be enhanced by the inclusion of fiber. The viscoelastic characteristics of fiber-reinforced asphalt binders and their corresponding mixtures were characterized in this study. To generate fiber-reinforced asphalt samples for dynamic shear rheometer (DSR) tests, polypropylene fibers (PPFs), polyester fibers (PFs), and lignin fibers (LFs) were added into modified asphalt with a ratio of 5wt%. Indirect tensile resilience tests were conducted on the fiber-reinforced asphalt mixture with Marshall samples, which was prepared with a 6.4% of bitumen/aggregate ratio. The addition of fiber can increase the anti-rutting performance of asphalt binders, and also reduce the anti-fatigue performance of asphalt binders to varying degrees. Viscoelastic properties of the fiber-reinforced asphalt binders are highly dependent on the shape of the used fiber. The resistance of the fiber-reinforced asphalt binders to rutting at high temperatures increases with the roughness degree of the fiber's surface morphology. PPF-reinforced asphalt binders surpass the others in terms of anti-rutting capabilities. The high-temperature deformation resistance of the PPF-reinforced asphalt mixture is stronger, whereas the low-temperature crack resistance of the PF-reinforced asphalt mixture is stronger, which can be observed from the master curve of indirect tensile resilient modulus.
Related Concept Videos
Fiber Reinforced Concrete
Additives and Fillers in Concrete
The...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Moisture Content and Bulking of Aggregate
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Elasticity in Concrete

