A Novel Approach of a Low-Cost Voltage Fault Injection Method for Resource-Constrained IoT Devices: Design and
Nicolás Ruminot1, Claudio Estevez1, Samuel Montejo-Sánchez2
1Department of Electrical Engineering, Universidad de Chile, Santiago 8940577, Chile.
Abstract:
The rapid development of the Internet of Things (IoT) has brought about the processing and storage of sensitive information on resource-constrained devices, which are susceptible to various hardware attacks. Fault injection attacks (FIAs) stand out as one of the most widespread. Particularly, voltage-based FIAs (V-FIAs) have gained popularity due to their non-invasive nature and high effectiveness in inducing faults by pushing the IoT hardware to its operational limits. Improving the security of devices and gaining a comprehensive understanding of their vulnerabilities is of utmost importance. In this study, we present a novel fault injection method and employ it to target an 8-bit AVR microcontroller. We identify the optimal attack parameters by analyzing the detected failures and their trends. A case study is conducted to validate the efficacy of this new method in a more realistic scenario, focusing on a simple authentication method using the determined optimal parameters. This analysis not only demonstrates the feasibility of the V-FIA but also elucidates the primary characteristics of the resulting failures and their propagation in resource-constrained devices. Additionally, we devise a hardware/software countermeasure that can be integrated into any resource-constrained device to thwart such attacks in IoT scenarios.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
09:36Open-Source Miniature Fluorimeter to Monitor Real-Time Isothermal Nucleic Acid Amplification Reactions in Resource-Limited Settings
Published on: February 3, 2021
Related Concept Videos
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Fault Types
For line-to-line faults occurring between phases B and C, the...
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...