Non-invasive continuous blood pressure prediction based on ECG and PPG fusion map
Huiquan Wang1, Mengting Han2, Chuwei Zhong2
1School of Life Sciences, TianGong University, Tianjin 300387, China; Tianjin Key Laboratory of Quality Control and Evaluation Technology for Medical Devices, Tianjin 300384, China.
Abstract:
To achieve real-time blood pressure monitoring, a novel non-invasive method is proposed in this article. Electrocardiographic (ECG) and pulse wave signals (PPG) are fused from a multi-omics signal-level perspective. A physiological signal fusion matrix and fusion map, which can estimate the blood pressure of blood loss(BPBL), are constructed. The results demonstrate the efficacy of the fusion map model, with correlation values of 0.988 and 0.991 between the estimated BPBL and the true systolic blood pressure (SBP) and diastolic blood pressure (DBP), respectively. The root mean square errors for SBP and DBP were 3.21 mmHg and 3.00 mmHg, respectively. The model validation showed that the fusion map method is capable of simultaneous highlighting of the respective characteristics of ECG and PPG and their correlation, improving the utilization of the information and the accuracy of BPBL. This article validates that physiological signal fusion map can effectively improve the accuracy of BPBL estimation and provides a new perspective for the field of physiological information fusion.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring