Abstract:
This study evaluated nuclear medicine occupational radiation doses at Sultan Qaboos University Hospital, a 700-bed tertiary care teaching hospital in Oman. Personal effective whole-body doses, Hp(10), and extremity doses, Hp(0.07), were collected for 19 medical radiation workers over a 7-year period (2015-2021). Personal doses for four professional groups were measured using calibrated thermo-luminescence dosemeters ((LiF:Mg,Ti) TLD-100). The average, median and maximum cumulative doses were compared against the annual whole-body and extremity dose limits (20 mSv and 500 mSv y-1, respectively) and local dose investigation level (DIL; 6 mSv y-1). Personal whole-body doses (average:median:maximum) for technologists, medical physicists, nuclear medicine physicians and nurses were 1.8:1.1:7.8, 0.3:0.3:0.4, 0.1:0.1:0.2 and 0.1:0.1:0.2 mSv, respectively. Personal extremity doses for left and right hand (average and maximum doses) follow similar trends. Average annual effective whole-body and extremity doses were well below the recommended annual dose limits. The findings suggest lowering local DIL for all staff except for technologists.
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Isotopes and Radioisotopes
An isotope containing...