Insights
Posterior urethral valve (PUV) can lead to kidney disease in children. Measured GFR (mGFR) is more reliable than estimated GFR (eGFR) methods for assessing kidney function in these patients.
Area of Science:
- Pediatric Nephrology
- Urology
- Diagnostic Medicine
Background:
- Posterior urethral valve (PUV) is a primary cause of obstructive uropathy in children, potentially leading to chronic kidney disease (CKD) and end-stage renal disease (ESRD).
- Glomerular filtration rate (GFR) is the gold standard for assessing renal function, but its direct measurement is often impractical.
- Estimated GFR (eGFR) methods using endogenous filtration markers are commonly used but may be inaccurate in pediatric PUV patients due to factors like growth retardation affecting creatinine production.
Purpose of the Study:
- To compare measured GFR (mGFR) with various creatinine-based estimated GFR (eGFR) methods in pediatric patients with PUV.
- To evaluate the accuracy of different eGFR equations in classifying CKD grades in this specific population.
Main Methods:
- A retrospective study of 62 pediatric patients treated for PUV post-fulguration.
- mGFR was determined using the 99mTc-diethylenetriaminepentaacetate (DTPA) in vitro method.
- Eight eGFR equations (Schwartz, Cockcroft-Gault [CG], Counahan-Barratt [CB], CKD-EPI, full-age spectrum [FAS] age, FAS height [FAS Ht], Schwartz-Lyon [SL], and height-independent) were compared against mGFR and CKD grades.
Main Results:
- A significant positive correlation (0.46-0.77) was observed between mGFR and eGFR values.
- eGFR methods showed variable accuracy in classifying CKD grades, with correct classification rates ranging from 25.8% to 51.6%.
- eGFR tended to overestimate GFR at lower levels and underestimate it at higher levels.
Conclusions:
- Creatinine-based eGFR methods have considerable limitations and should not entirely replace mGFR measurement in pediatric PUV patients.
- An initial mGFR measurement followed by serial eGFR monitoring is recommended.
- Specific eGFR equations demonstrated better accuracy for certain CKD grades: CB for Grade II, SL or height-independent for Grade III, FAS age for Grade IV, and SL for Grade V.
Background:
Posterior urethral valve (PUV) is obstructive uropathy that may lead to chronic kidney disease (CKD) and end-stage renal disease (ESRD) in children. Glomerular filtration rate (GFR) measurement remains the gold standard for renal function measurement. However, due to its less availability and cumbersome, it is not commonly used, and GFR is estimated utilizing various endogenous filtration markers.
Objective:
This study includes pediatric patients with PUV. We aimed to compare the measured GFR (mGFR) with various creatinine-based estimated GFR methods (eGFR).
Materials And Methods:
A single-center retrospective study included 62 treated cases of PUV, postvalve fulguration. The mGFR measured by 99mTc-diethylenetriaminepentaacetate in vitro method and compared with eight eGFR (Schwartz, Cockcroft-Gault [CG], Counahan-Barratt [CB], CKD Epidemiology Collaboration [CKD-EPI], full-age spectrum [FAS] age, FAS height (FAS Ht), Schwartz-Lyon [SL], and Ht independent). Patients were subdivided into different CKD grades and compared with various eGFR.
Discussion:
PUV is a common cause of CKD in children and needs special consideration as there is growth retardation associated with it. It decreases creatinine production and thus fallacies in eGFR measurement. There is a requisite to identify and closely monitor the subset of patients with baseline decreased renal function and therefore at risk of developing ESRD.
Results:
A total of 62 patients were included. Mean age and serum creatinine levels were 8.02 ± 5.53 years and 1.15 ± 0.95 mg/dl (range: 0.4-4.5), respectively. The mean mGFR was 61.6 ± 31.80 mL/min/1.73 m2 and a positive variable correlation was 0.46-0.77 between mGFR and eGFR. Based on mGFR, there were 14 (22.6%), 21 (33.8%), 13 (20.9%), 9 (14.5%), and 5 (8.1%) patients in Grades I-V, respectively. The correct classification of the CKD grades was noted in 25 (40.3%), 16 (25.8%), 32 (51.6%), 16 (25.8%), 25 (40.3%), 27 (43.5%), 26 (41.9%), and 28 (45.2%) patients by Schwartz, CG, CB, CKD-EPI, FAS age, FAS Ht, SL, and Ht-independent equation. The eGFR overestimates GFR at the lower level and underestimates at higher levels.
Conclusion:
Our results confirm the considerable limitations of various creatinine-based clearance methods for estimating actual GFR. The creatinine clearance-based eGFR should not replace the measurement of the GFR. An initial measure of the mGFR followed by serial follow-up with the eGFR equation may be done. The most accurate eGFR equations are CB for Grade II, SL or Ht independent for Grade III, FAS age for Grade IV, and SL for Grade V CKD.
Related Concept Videos
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Urodynamic Studies: Uroflowmetry
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...