Technical-economic and environment benefit analyses of a novel building attached photovoltaic system

Gang Wang1, Yuechao Chao2, Jianqing Lin2

  • 1School of Energy and Power Engineering, Northeast Electric Power University, Jilin, 132012, Jilin, China. kinggang009@163.com.

Related Concept Videos

P-N junction01:11

P-N junction

A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
571
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
201
Design Example: Sustainability in Concrete Building01:26

Design Example: Sustainability in Concrete Building

As the construction industry moves towards more eco-friendly practices, concrete's adaptability and its ability to incorporate sustainable features make it a key material in the drive towards greener building solutions.
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
188
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
136
Power in a Three-Phase Circuit01:15

Power in a Three-Phase Circuit

Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
356
Three-Phase Circuits01:22

Three-Phase Circuits

AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
435