Related Experiment Video
Updated: Jul 28, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects
Varmeet Kaur1, Meena Makhija1, Vandana Phadke2
1Indian Spinal Injuries Centre, Institute of Rehabilitation Sciences, New Delhi, India.
Context:
Clinical assessment of scapular motion is obscured by a lack of clinically accessible and feasible angular measurement tools. This study evaluates the reliability and validity of the smartphone "Clinometer" app in measuring scapular upward rotation (UR) and anteroposterior tilt.
Design:
Psychometric analysis.
Methods:
We recruited 57 participants-10 with and 47 without shoulder pain. Two physical therapists consecutively measured both scapular movements using the Clinometer app at the arm by the side (rest), 30°, 60°, 90°, and 120° of humeral elevation in the scapular plane; one therapist measured again after 2 days. For evaluating concurrent validity, we compared the Clinometer scores with those measured using an electromagnetic motion capture system in 10 healthy participants. Intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable difference at 90% confidence intervals (MDD90) were calculated. Concurrent validity was evaluated using repeated-measures analysis of variance followed by post hoc testing with Tukey-Kramer test (P < .05).
Results:
We observed good intrarater reliability (ICC: UR = .76-.85, tilt = .69-.9; SEM: 2.2°-3.5°; MDD90: ∼5°-8°) and moderate to good interrater reliability (ICC: UR = .66-.78, tilt = .66-.76; SEM: 3.6°-8°; MDD90: ∼9°-18°) for both rotations. The Clinometer scores for UR were comparable to electromagnetic motion capture system at all angles except 90° (difference ∼8°); for scapular tilt, the scores were comparable only at rest and 30° elevation.
Conclusion:
The Clinometer app is reliable and valid for measuring scapular UR throughout and for scapular tilt at lower humeral elevation angles. The MDD90 values for scapular rotations computed in this study can be helpful in rehabilitation planning and future research.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...

