Biceps muscle injury associated with non-invasive automatic blood pressure monitoring
Rose Nicol1, Ian Lin2, Linga Prasad3
1Emergency Department, Toowoomba Hospital, Darling Downs Health, Toowoomba, Queensland, Australia rose.nicol.53@gmail.com.
Abstract:
This case describes a young, healthy woman who developed a grade 1 biceps muscle strain after the use of automatic non-invasive blood pressure monitoring during an elective surgical procedure. She was treated conservatively with simple analgesia, physiotherapy and a sling for comfort. Follow-up conducted 1 week later revealed occasional soreness, but she had almost returned to her baseline activity. The patient made a full recovery without any residual symptoms by the end of 6 weeks. This case highlights the importance of careful monitoring to ensure that routine use of blood pressure cuffs does not cause any pressure injuries.
More Related Videos
09:33A Methodological Approach to Non-invasive Assessments of Vascular Function and Morphology
Published on: February 7, 2015
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...