Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Evaluation of standard breast ultrasonography by adding two-dimensional and three-dimensional shear wave
Jinshun Xu1,2, Lei Zhang3, Wen Wen1
1Department of Ultrasound Medicine, Institute of Ultrasound Medicine, West China Hospital of Sichuan University, Chengdu, China.
Objective:
To reduce the number of biopsies performed on benign breast lesions categorized as BI-RADS 4-5, we investigated the diagnostic performance of combined two-dimensional and three-dimensional shear wave elastography (2D + 3D SWE) with standard breast ultrasonography (US) for the BI-RADS assessment of breast lesions.
Methods:
A total of 897 breast lesions, categorized as BI-RADS 3-5, were subjected to standard breast US and supplemented by 2D SWE only and 2D + 3D SWE analysis. Based on the malignancy rate of less than 2% for BI-RADS 3, lesions assessed by standard breast US were reclassified with SWE assessment.
Results:
After standard breast US evaluation, 268 (46.1%) participants underwent benign biopsies in BI-RADS 4-5 lesions. By using separated cutoffs for upstaging BI-RADS 3 at 120 kPa and downstaging BI-RADS 4a at 90 kPa in 2D + 3D SWE reclassification, 123 (21.2%) participants underwent benign biopsy, resulting in a 54.1% reduction (123 versus 268).
Conclusion:
Combining 2D + 3D SWE with standard breast US for reclassification of BI-RADS lesions may achieve a reduction in benign biopsies in BI-RADS 4-5 lesions without sacrificing sensitivity unacceptably.
Clinical Relevance Statement:
Combining 2D + 3D SWE with US effectively reduces benign biopsies in breast lesions with categories 4-5, potentially improving diagnostic accuracy of BI-RADS assessment for patients with breast lesions.
Trial Registration:
ChiCTR1900026556 KEY POINTS: • Reduce benign biopsy is necessary in breast lesions with BI-RADS 4-5 category. • A reduction of 54.1% on benign biopsies in BI-RADS 4-5 lesions was achieved using 2D + 3D SWE reclassification. • Adding 2D + 3D SWE to standard breast US improved the diagnostic performance of BI-RADS assessment on breast lesions: specificity increased from 54 to 79%, and PPV increased from 54 to 71%, with slight loss in sensitivity (97.2% versus 98.7%) and NPV (98.1% versus 98.7%).
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...