Inter- and intra-observer reliability of thoracic limb circumference measurement methods in sound dogs
Kelly Deabold1, Jordan Harriz1, Brandy Madeiros1
1Department of Comparative, Diagnostic and Population Medicine, University of Florida College of Veterinary Medicine, Gainesville, FL, United States.
Objective:
The primary objectives of this study are to (1) compare the inter- and intra-observer reliability of thoracic limb circumference measurement methods in sound dogs, and (2) determine the most reliable thoracic limb positioning and location on the thoracic limb for performing circumferential measurements.
Methods:
Thoracic limbs of 10 apparently sound dogs (20 limbs) were blindly and independently measured by 3 observers. Triplicate measurements were performed with dogs in lateral recumbency at 50 and 70% brachial (Br) length (length between the greater tubercle and lateral humoral epicondyle) and 25% ABr length (length between the lateral humeral epicondyle and ulnar styloid process), both with the elbow extended and at an approximate weight-bearing (WB) angle. Intra-class correlation coefficients (ICC) with a 95% confidence interval (CI) were used for data analysis with a p < 0.05 being significant.
Results:
All measures had significantly good to excellent intra- (ICC 0.836-0.994, p < 0.001) and inter-observer reliability (ICC 0.834-0.996, p < 0.001). Inter-observer reliability was excellent at 25% ABr extended and WB positions, and at 50% Br WB position, with a wider confidence interval at the latter location. Intra-observer reliability was excellent across all observers for 25% ABr extended and WB, and 50% Br WB positions, also with a wider confidence interval at the latter location.
Conclusion:
Circumferential measurement of the canine thoracic limb was most reliable at 25% ABr length with the elbow either in an extended or WB position.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement