Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
A Prospective Comparison of Standard Technique, Doppler Ultrasonography, and Pressure Waveform Analysis for
Yonatan Y Greenstein1, Scott Ferrara1, Jerry Jomi1
1Division of Pulmonary and Critical Care Medicine, Department of Medicine, Rutgers New Jersey Medical School, Newark, NJ, USA.
Abstract:
Purpose: Intraosseous (IO) catheters allow healthcare workers to rapidly administer fluids and medications to critically ill patients when intravenous access is inadequate or unable to be obtained. An improperly placed IO catheter can lead to delays in care, as well as serious complications such as limb necrosis. Methods: In this single-center, prospective, observational study, we compared 2 established methods of confirming proper IO catheter placement to a novel pressure waveform analysis technique in which the IO catheter is attached to a standard pressure transducer. Attaching a pressure transducer to a properly placed IO catheter produces a pulsatile waveform. Misplacement of the IO catheter produces a flatline waveform. Results: Of 42 IO catheters, 8 (19%) were incorrectly placed per the waveform analysis technique. Compared to the pressure waveform analysis technique, the standard method and the power Doppler method incorrectly classified 4/8 (50%) and 5/8 (62.5%) of the misplaced catheters, respectively. The standard method had a higher positive predictive value for detecting incorrectly placed IO catheters than the power Doppler method (100% vs 63%, respectively). Blinded reviewers demonstrated better agreement using the pressure waveform analysis technique than using power Doppler (k = 0.77 vs k = 0.58, respectively). Conclusion: The standard and power Doppler ultrasonography techniques identify incorrectly placed IO catheters sub-optimally. The pressure waveform analysis technique is more accurate than the standard of care and has superior interrater agreement compared to the ultrasound method of confirmation. With more than 500 000 IO catheters placed in the United States each year, this novel technique may improve overall IO safety. Trial Registration Number: NCT03908879.
More Related Videos
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
06:27Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiac Catheterization III: Left Heart Catheterization
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)