Related Experiment Video
Updated: Jul 17, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Late detachment of ascending aortic graft mimicking pseudoaneurysm and dissection: A case report
Renato Fabrizio1, Laura Mascitti1, Sara Boemi1
1Postgraduation School in Radiodiagnostics, Università degli Studi di Milano, Via Festa del Perdono 7, 20122, Milan, Italy.
Abstract:
Ascending aorta aneurysm is a pathological dilatation of the aortic wall which needs in most cases surgical treatment. Complications after surgery are usually rare events and include infections, bleeding, and pseudoaneurysm. We present a report of a late complication after ascending aorta aneurysm repair consisting of a prosthetic detachment and dislocation miming a pseudoaneurysm of the aortic root associated with an aortic dissection. This case was radiologically challenging due to the atypical CT aspect and therefore it required a deep radiological, clinical, and surgical analysis with a multidisciplinary approach.