Related Experiment Video
Updated: Jul 17, 2025

Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020
Factors Associated With Initiation of Mechanical Ventilation in Patients With Sepsis: Retrospective Observational
Robert E Freundlich1, Gen Li2, Aleda Leis3
1Robert E. Freundlich is an associate professor, Department of Anesthesiology, Vanderbilt University Medical Center, Nashville, Tennessee.
Background:
Patients with sepsis are at risk for mechanical ventilation. This study aimed to identify risk factors for initiation of mechanical ventilation in patients with sepsis and assess whether these factors varied with time.
Methods:
Data from the electronic health record were used to model risk factors for initiation of mechanical ventilation after the onset of sepsis. A time-varying Cox model was used to study factors that varied with time.
Results:
Of 35 020 patients who met sepsis criteria, 28 747 were eligible for inclusion. Mechanical ventilation was initiated within 30 days after sepsis onset in 3891 patients (13.5%). Factors that were independently associated with increased likelihood of receipt of mechanical ventilation were race (White: adjusted hazard ratio [HR], 1.59; 95% CI, 1.39-1.83; other/unknown: adjusted HR, 1.97; 95% CI, 1.54-2.52), systemic inflammatory response syndrome (adjusted HR [per point], 1.23; 95% CI, 1.17-1.28), Sequential Organ Failure Assessment score (adjusted HR [per point], 1.28; 95% CI, 1.26-1.31), and congestive heart failure (adjusted HR, 1.30; 95% CI, 1.17-1.45). Hazard ratios decreased with time for Sequential Organ Failure Assessment score and congestive heart failure and varied with time for 4 comorbidities and 3 culture results.
Conclusions:
The risk for mechanical ventilation associated with different factors varied with time after sepsis onset, increasing for some factors and decreasing for others. Through a better understanding of risk factors for initiation of mechanical ventilation in patients with sepsis, targeted interventions may be tailored to high-risk patients.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: